Yep, you got it.

Jeff

On Fri, Jun 19, 2009 at 04:15:41PM -0700, Simon Breden wrote:
> Hi,
> 
> I have a ZFS storage pool consisting of a single RAIDZ2 vdev of 6 drives, and 
> I have a question about replacing a failed drive, should it occur in future.
> 
> If a drive fails in this double-parity vdev, then am I correct in saying that 
> I would need to (1) unplug the old drive once I've identified the drive id 
> (c1t0d0 etc), (2) plug in the new drive on the same SATA cable, and (3) issue 
> a 'zpool replace pool_name drive_id' command etc, at which point ZFS will 
> resilver the new drive from the parity data ?
> 
> Thanks,
> Simon
> -- 
> This message posted from opensolaris.org
> _______________________________________________
> zfs-discuss mailing list
> zfs-discuss@opensolaris.org
> http://mail.opensolaris.org/mailman/listinfo/zfs-discuss
_______________________________________________
zfs-discuss mailing list
zfs-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/zfs-discuss

Reply via email to