Yep, you got it. Jeff
On Fri, Jun 19, 2009 at 04:15:41PM -0700, Simon Breden wrote: > Hi, > > I have a ZFS storage pool consisting of a single RAIDZ2 vdev of 6 drives, and > I have a question about replacing a failed drive, should it occur in future. > > If a drive fails in this double-parity vdev, then am I correct in saying that > I would need to (1) unplug the old drive once I've identified the drive id > (c1t0d0 etc), (2) plug in the new drive on the same SATA cable, and (3) issue > a 'zpool replace pool_name drive_id' command etc, at which point ZFS will > resilver the new drive from the parity data ? > > Thanks, > Simon > -- > This message posted from opensolaris.org > _______________________________________________ > zfs-discuss mailing list > zfs-discuss@opensolaris.org > http://mail.opensolaris.org/mailman/listinfo/zfs-discuss _______________________________________________ zfs-discuss mailing list zfs-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/zfs-discuss