On Mon, Aug 24, 2009 at 02:01:39PM -0500, Bob Friesenhahn wrote: > On Mon, 24 Aug 2009, Albert Chin wrote: >> >> Seems some of the new drives are having problems, resulting in CKSUM >> errors. I don't understand why I have so many data errors though. Why >> does the third raidz2 vdev report 34.0K CKSUM errors? > > Is it possible that this third raidz2 is inflicted with a shared > problem such as a cable, controller, backplane, or power supply? Only > one drive is reported as being unscathed.
Well, we're just using unused drives on the existing array. No other changes. > Do you periodically scrub your array? No. Guess we will now :) But, I think all of the data loss is a result of the new drives, not ones that were already part of the two previous vdevs. -- albert chin (ch...@thewrittenword.com) _______________________________________________ zfs-discuss mailing list zfs-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/zfs-discuss