On Mon, Aug 24, 2009 at 02:01:39PM -0500, Bob Friesenhahn wrote:
> On Mon, 24 Aug 2009, Albert Chin wrote:
>>
>> Seems some of the new drives are having problems, resulting in CKSUM
>> errors. I don't understand why I have so many data errors though. Why
>> does the third raidz2 vdev report 34.0K CKSUM errors?
>
> Is it possible that this third raidz2 is inflicted with a shared
> problem such as a cable, controller, backplane, or power supply? Only
> one drive is reported as being unscathed.

Well, we're just using unused drives on the existing array. No other
changes.

> Do you periodically scrub your array?

No. Guess we will now :) But, I think all of the data loss is a result
of the new drives, not ones that were already part of the two previous
vdevs.

-- 
albert chin (ch...@thewrittenword.com)
_______________________________________________
zfs-discuss mailing list
zfs-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/zfs-discuss

Reply via email to