On Wed, Mar 3, 2010 at 5:57 PM, Bob Friesenhahn < bfrie...@simple.dallas.tx.us> wrote:
> On Thu, 4 Mar 2010, Christian Heßmann wrote: > >> To be honest, I don't know how to proceed now. It feels like my system is >> in a very unstable state right now, with a replacement not yet finished and >> errors on two drives in one RAID.Z1. >> > > If it is still in 'replacing' mode then it seems that the best policy is to > just wait. If there is no drive activity on ad4p2 then there may be > something more wrong. > > Cold booting a system can be one of the scariest things to do so it should > be a means of last resort. Maybe the system would not come back. > We've had this happen a couple of times on our FreeBSD-based storage servers. Rebooting and manually running a scrub has fixed the issue each time. 24x 500 GB SATA drives in 3x raidz2 vdev of 8 drives each -- Freddie Cash fjwc...@gmail.com
_______________________________________________ zfs-discuss mailing list zfs-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/zfs-discuss