https://bugzilla.kernel.org/show_bug.cgi?id=215882

            Bug ID: 215882
           Summary: Battery not charging, Nuvision Solo 10 Draw (Intel
                    Cherry Trail, battery INT33F4)
           Product: ACPI
           Version: 2.5
    Kernel Version: 5.17.4
          Hardware: x86-64
                OS: Linux
              Tree: Mainline
            Status: NEW
          Severity: normal
          Priority: P1
         Component: Power-Battery
          Assignee: acpi_power-batt...@kernel-bugs.osdl.org
          Reporter: gero3...@gmail.com
        Regression: No

Created attachment 300797
  --> https://bugzilla.kernel.org/attachment.cgi?id=300797&action=edit
acpidump

My issue seems remarkably similar to this issue filed here. But with a
different tablet computer, the Nuvision Solo 10 Draw.

https://bugzilla.redhat.com/show_bug.cgi?id=1610545

Running the following commands as root from that page

modprobe i2c-dev
i2cset -y -f 6 0x34 0x82 0xf0
i2cset -y -f 6 0x34 0x84 0xf0

seems to solve the issue allowing the battery to charge and stopping the red
light indicator from blinking.