Hi, Had something like that. Turned, in our case, out to be a defect of the "mount ready" sensor in the drive. In our case it was a IBM 3584 library with LTO1 fiber drives.
Regards, Karel -----Oorspronkelijk bericht----- Van: Warren, Matthew (Retail) [mailto:[EMAIL PROTECTED] Verzonden: donderdag 19 februari 2004 12:06 Aan: [EMAIL PROTECTED] Onderwerp: Volume mounts but TSM doesnt use it Hello TSM'ers, We have a situation where every now and again a tape will mount, but the process requesting the tape remains in a state of 'Waiting for mount of volume', I've searched IBM for any hints but haven't found any so far; A trace of the event looks like this; 09:34:56.350 [178][asvolmnt.c][2993]: Mounting active volume SH0313(4876), side 0, pool ONSITE_MNT(17). 09:34:56.600 [58][mms.c][909]: Mounting volume SH0313 in library 3584_SHWD; 09:34:56.608 [58][mmslib.c][5920]: Testing for existence of volume SH0313 in library 3584_SHWD. 09:34:56.608 [58][mmslib.c][5957]: Volume SH0313 exists in library 3584_SHWD; stat=1, use=1. 09:34:56.615 [58][mmsscsi.c][9096]: Preparing private volume SH0313 in library 3584_SHWD. 09:34:56.620 [58][mmslib.c][7965]: Obtaining reservation for volume SH0313 in library 3584_SHWD; activity=4. 09:34:56.841 [58][mmsscsi.c][8548]: Beginning volume use; lib=3584_SHWD, vol=SH0313, element=260. 10:35:54.138 [58][mmsscsi.c][8717]: Ending volume use; lib=3584_SHWD, vol=SH0313. 10:35:54.159 [58][mmslib.c][8058]: Releasing reservation for volume SH0313 in library 3584_SHWD. You can see, 09:34 mmsscsi issues a 'Beginning volume use' message, but the process never seems to actually start to use the tape, and then, an hour later (The mountW time set on the server for this devclass) the tape is dismounted.. Has anyone seen this behaviour before? LTO1 drives, 3584 library, AIX server at 5.1.5.4 Any help much appreciated! Thanks, Matthew. ___________________________ Disclaimer Notice __________________________ This message and any attachments are confidential and should only be read by those to whom they are addressed. If you are not the intended recipient, please contact us, delete the message from your computer and destroy any copies. Any distribution or copying without our prior permission is prohibited. Internet communications are not always secure and therefore the Powergen Group does not accept legal responsibility for this message. The recipient is responsible for verifying its authenticity before acting on the contents. Any views or opinions presented are solely those of the author and do not necessarily represent those of the Powergen Group. Registered addresses: Powergen UK plc, 53 New Broad Street, London, EC2M 1SL Registered in England & Wales No. 2366970 Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry CV4 8LG. Registered in England and Wales No: 3407430 Telephone +44 (0) 2476 42 4000 Fax +44 (0) 2476 42 5432