I've reached my first tape change on my autochangers, yeah!
But...
24-Jan 17:22 cnpve3-sd JobId 16234: [SI0202] End of Volume "AAJ661L9" at
333:49131 on device "LTO9Storage0" (/dev/nst0). Write of 524288 bytes got -1.
24-Jan 17:22 cnpve3-sd JobId 16234: Re-read of last block succeeded.
24-Jan 17:22 cnpve3-sd JobId 16234: End of medium on Volume "AAJ661L9"
Bytes=17,846,022,566,912 Blocks=34,038,588 at 24-Jan-2024 17:22.
24-Jan 17:22 cnpve3-sd JobId 16234: 3307 Issuing autochanger "unload Volume
AAJ661L9, Slot 2, Drive 0" command.
24-Jan 17:28 cnpve3-sd JobId 16234: 3995 Bad autochanger "unload Volume
AAJ661L9, Slot 2, Drive 0": ERR=Child died from signal 15: Termination
Results=Program killed by Bacula (timeout)
24-Jan 17:28 cnpve3-sd JobId 16234: 3304 Issuing autochanger "load Volume
AAJ660L9, Slot 1, Drive 0" command.
24-Jan 17:29 cnpve3-sd JobId 16234: 3305 Autochanger "load Volume AAJ660L9,
Slot 1, Drive 0", status is OK.
So, unload timeout, but subsequent load command works as expected (and
backup are continuing...).
I can safely ignore this? Better tackle with tiemout parameters on
/etc/bacula/scripts/mtx-changer.conf script?
Thanks.
--
Ci vuole sempre qualcuno da odiare per sentirsi giustificati
nella propria miseria. (Umberto Eco)
_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users