I edited the names and the device-names:
Device {
Name = "HP-Ultrium4"
MediaType = "LTO-4"
DeviceType = "Tape"
ArchiveDevice = "/dev/tape/by-id/scsi-350014380032d5e61-nst"
LabelMedia = yes
AlwaysOpen = yes
Autochanger = yes
MaximumFileSize = 20000000000
}
Autochanger {
Name = "HP-Autoloader"
Description = "HP 1x8 G2 AUTOLDR"
Device = "HP-Ultrium4"
ChangerDevice = "/dev/tape/by-id/scsi-350014380032d5e60-changer"
ChangerCommand = "/etc/bacula/scripts/mtx-changer %c %o %S %a %d"
}
# lsscsi -g
[0:0:0:0] disk VMware Virtual disk 2.0 /dev/sda /dev/sg0
[1:0:0:0] tape HP Ultrium 4-SCSI U62W /dev/st0 /dev/sg2
[1:0:0:1] mediumx HP 1x8 G2 AUTOLDR 4.80 /dev/sch0 /dev/sg3
[4:0:0:0] cd/dvd NECVMWar VMware SATA CD00 1.00 /dev/sr0 /dev/sg1
/etc/bacula/scripts/mtx-changer /dev/sg3 slots
8
# /usr/sbin/bconsole
Connecting to Director localhost:9101
1000 OK: 103 debian1-dir Version: 9.6.7 (10 December 2020)
Enter a period to cancel a command.
*status slots
Automatically selected Storage: HP-Autoloader
Automatically selected Catalog: MyCatalog
Using Catalog "MyCatalog"
Connecting to Storage daemon HP-Autoloader at localhost:9103 ...
3306 Issuing autochanger "slots" command.
Device "HP-Autoloader" has 0 slots.
No slots in changer to scan.
_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users