Hi.
I have the log when bacula finish Job.
the Job finish with stauts OK but with Warning.
LOG:
15-May 10:05 backup-sd JobId 92: Error: Error syncing volume "IMS0502L6" on
device "DRIVE3" (/dev/tape/by-id/scsi-3200a000e11161f33-nst). ERR=Invalid
argument.
Library IBM ts3200 3 drive lto6 and 48 slots. conect: FC
It happens with the 4 drive.
My SD:
Autochanger {
Name = "TS3200"
Device = "DRIVE0"
Device = "DRIVE1"
Device = "DRIVE2"
Device = "DRIVE3"
ChangerDevice = "/dev/tape/by-id/scsi-1IBM_3573-TL_00L4U78W4076_LL0"
ChangerCommand = "/opt/bacula/scripts/mtx-changer %c %o %S %a %d"
}
N+4
Device {
Name = "DRIVE"
MediaType = "LTO-6"
DeviceType = "Tape"
ArchiveDevice = "/dev/tape/by-id/scsi-3200a000e11161f33-nst"
RemovableMedia = yes
RandomAccess = no
AutomaticMount = yes
AlwaysOpen = yes
Autochanger = yes
ChangerCommand = "/opt/bacula/scripts/mtx-changer %c %o %S %a %d"
AlertCommand = "sh -c 'smartctl -H -l error %c'"
DriveIndex = 3
AutoSelect = yes
}
thanks.
--
#############################