Hi,

czw., 2 sty 2025 o 12:41 Arno Lehmann via Bacula-users <
[email protected]> napisał(a):

> Hello Borut,
>
> Am 21.12.2024 um 13:52 schrieb Borut Rozman via Bacula-users:
> > Hi there,
> > This question might be answered somewhere but I didn’t find the proper
> source to find it out.
>
> It may not be answered explicitly, but all the needed capabilities are
> simply part of the core Bacula feature set.
>

Depending on the requirements. If a customer wants to follow LTO read/write
compatibility list then Bacula can't support this in some scenarios.
For example when you have LTO6 and LTO4 drives and LTO6 and LTO4
cartridges, your compatibility list say:
- LTO6 drive -> LTO6 R/W + LTO4 RO
- LTO4 drive -> LTO4 RW
Can you get read-only for LTO4 cartridge at LTO6 drive in this case?
I'm unable to set this up. I had the same limitation during ACSLS in BEE
development.

best regards
-- 
Radosław Korzeniewski
[email protected]
_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to