On 10/29/2016 10:12 PM, Hadi Motamedi wrote:
I am using a centos server for cdr billing and mediation device on a remote
network. I am experiencing problem that I am suspicious it comes from main
supply power cut at the remote site. The power supply to the remote site
comes from battery charger that will be automatically switched in circuit
under main supply power cut but cannot provide adequate power for more than
2 hours . I am suspicious that the remote system is suffering from many
frequent main supply power cut . Can you please do me favor and let me know
if there is any log on my centos server that I can check to see if there
would be many frequent power cut there ?

look at /var/log/messages for reboots without shutdowns.

centos 6 linux boot starts logging something like...

Oct 25 15:01:25 new kernel: imklog 5.8.10, log source = /proc/kmsg started.
Oct 25 15:01:25 new rsyslogd: [origin software="rsyslogd" swVersion="5.8.10" x-pid="2740" x-info="http://www.rsyslog.com";] start
Oct 25 15:01:25 new kernel: Initializing cgroup subsys cpuset
Oct 25 15:01:25 new kernel: Initializing cgroup subsys cpu
Oct 25 15:01:25 new kernel: Linux version 2.6.32-642.6.1.el6.x86_64 (mockbu...@worker1.bsys.centos.org) (gcc version 4.4.7 20120313 (Red Hat 4.4.7-17) (GCC) ) #1 SMP Wed Oct 5 00:36:12 UTC 2016


followed by tons more about all the stuff starting up....


when its properly shutdown, you'd see something like this after everything has stopped

Oct 25 14:20:36 new init: Disconnected from system bus
Oct 25 14:20:38 new rpcbind: rpcbind terminating on signal. Restart with "rpcbind -w"
Oct 25 14:20:38 new auditd[2704]: The audit daemon is exiting.
Oct 25 14:20:38 new kernel: type=1305 audit(1477430438.399:37765): audit_pid=0 old=2704 auid=4294967295 ses=4294967295 res=1 Oct 25 14:20:38 new kernel: type=1305 audit(1477430438.497:37766): audit_enabled=0 old=1 auid=4294967295 ses=4294967295 res=1
Oct 25 14:20:38 new kernel: Kernel logging (proc) stopped.
Oct 25 14:20:38 new rsyslogd: [origin software="rsyslogd" swVersion="5.8.10" x-pid="2738" x-info="http://www.rsyslog.com";] exiting on signal 15.


if its booted without a clean shutdown, it will do some file system checking and such while starting.


--
john r pierce, recycling bits in santa cruz