> where you're not allowed copper, like oil refineries
> where copper cable won't work due to massive interference
> where you must have runs to desktops that are over 90m (tho I've some 
> long runs on cat6 that work at 100M, just keep them below 200m, and use 
> quality cable)

Now that 10G over copper Cat6a (802.3an 10GBASE-T) has been finalized there 
aren't any good reason to go with fiber except for physical requirements like 
Ian stated. Also Desktop fiber aggregation is much more expensive in terms of 
line cards, diversity of switch choices, lack of desktop NICs. Usually I hear 
FTTD being done to "future proof" the wiring. Most of the times the fiber never 
ends up being used. Cat6a is backwards compatible with 5e, so if you are doing 
a new wiring plant, that's enough "future proof" for the next reasonable term.

----
Matthew Huff       | One Manhattanville Rd
OTA Management LLC | Purchase, NY 10577
http://www.ox.com  | Phone: 914-460-4039
aim: matthewbhuff  | Fax:   914-460-4139