-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Dear Sze Yi,

I think Rupp-validation might be more helpful than a score cut-off in
your case:

Would you take a drug developed based on how the ligand fits the
density you are observing?

Best,
Tim

On 04/28/2015 11:41 AM, Lau Sze Yi (SIgN) wrote:
> Hi,
> 
> I fitted small molecule ligand into observed electron density using
> the Find Ligands function and did a density fit analysis. What is
> considered an acceptable score?
> 
> Regards, Sze Yi
> 
> Research Fellow Singapore Immunology Network (SigN) 8A Biomedical
> Grove, #03-06 Immunos, Singapore 138648 DID: +65 6407 0640 Fax:
> +65 6407 0640
> 
> 

- -- 
- --
Dr Tim Gruene
Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen
phone: +49 (0)551 39 22149

GPG Key ID = A46BEE1A