Package: acpitool
Version: 0.5.1-2
Severity: normal

Hello,

I have installed a new laptop on a HP ProBook 6360b and for a while
the acpitool reported the correct state of the battery. But today it
started to report "Unknown, 97.00%". Charging the battery for hours do
not update the percentage.

If I disconnect the battery then acpitool correctly display
discharging and the percentage is decreasing (but the time remaining
is not computed because it stays at 00:00:00).

-- System Information:
Debian Release: wheezy/sid
  APT prefers unstable
  APT policy: (500, 'unstable')
Architecture: amd64 (x86_64)

Kernel: Linux 2.6.39-2-amd64 (SMP w/4 CPU cores)
Locale: LANG=fr_BE.UTF-8, LC_CTYPE=fr_BE.UTF-8 (charmap=UTF-8)
Shell: /bin/sh linked to /bin/dash

Versions of packages acpitool depends on:
ii  libc6                         2.13-10    Embedded GNU C Library: Shared lib
ii  libgcc1                       1:4.6.1-5  GCC support library
ii  libstdc++6                    4.6.1-5    GNU Standard C++ Library v3

Versions of packages acpitool recommends:
ii  acpid                         1:2.0.10-1 Advanced Configuration and Power I

acpitool suggests no packages.

-- no debconf information



-- 
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org