Hi,

thanks for the patch. Changed/cleanup-ed version commited.

Thanks,
Alex

> Am 28.06.2016 um 10:44 schrieb Kannel Neo <kneo...@gmail.com>:
> 
> Hi all,
> 
> We are running a very high performance Kannel instance (>1000 messages/second 
> at times).
> 
> We are finding throttling errors from our upstream suppliers because the load 
> counters inside Kannel are too imprecise, being that they only update after 1 
> second due to the fact that they are using time in seconds.
> 
> For example, you set the throughput of your SMPP bind to 200 per second, if 
> you have a fast machine, your bind can send more than 200 messages in a 
> second and then only subsequently realise (as the second ticks over) that it 
> has exceeded the throughput and waiting.
> 
> Herewith the attached patch which will allow precision load timers to update 
> these rates intra-second.
> 
> We are using this and find it helps a great deal.
> 
> Thanks
> <precision_timing.patch>


Reply via email to