Another thing to check is corrosion resistance at the battery contacts. I find this problem frequently with flash LED head-mounted lights.

When I have a problem like this, I like to measure the cell voltages under load. You may be able to run the KX3 into a dummy load at the 0,1W tune setting and measure each cell. If one cell shows significantly lower voltage, it is the problem. Running this test again several days after the battery was last charged will show cells which have high internal self-discharge.

73 Bill AE6JV

On 5/6/16 at 3:06 AM, p...@ieee.org (LA7NO) wrote:

KX3 (ser. no. 08146) works OK on external power, but recently I am
experiencing problem using it on internal rechargeable cells.

The AA cells are relatively new Varta Professional No. 5706, 2700 mAh NiMH.
They have been charged with a techno-line BC-1000. Measured capacity via an
automatic discharge/recharge cycle is according to spec.

I have attached a 50 Ohm dummy-load to the KX3. When turned on, it indicates
BT 9,7V.  BAT MIN is set to 8,2V.
When I press ATU TUNE, it turn itself off immediately.
With TUN PWR set to 0,1W it works OK when pressing TUNE, but BT drops to
7,6V.
If TUN PWR is set to 1W, it switches off when TUNE is pressed.

Strange that the voltage drops so much, even if the charger indicated normal
cell capacity when automatically discharging them.

-----------------------------------------------------------------------
Bill Frantz        | Since the IBM Selectric, keyboards have gotten
408-356-8506       | steadily worse. Now we have touchscreen keyboards.
www.pwpconsult.com | Can we make something even worse?

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to