On 18.06.2022 01:47, andy pugh wrote:
> On Fri, 17 Jun 2022 at 17:07, Jose Luis <[email protected]> wrote:
>
>> Still need to figure the parts from linuxcnc like where i can get or put
>> the data.
>
> Dewey added an interface. I'll be honest and say that it isn't how I
> would have done it. But I didn't do it so....
>
> https://linuxcnc.org/docs/devel/html/tooldatabase/tooldatabase.html
>
I was looking at these tables, and beside that table names are written
in plural form, the tools table with entries
toolID TEXT PRIMARY KEY,
T_number INTEGER,
As this is described, it seems to me that toolID really is a description,
and T_number could be used as the primary key, like so
toolID INTEGER PRIMARY KEY, -- alias T_number
description TEXT
Does this suggestion has any unintended side effect? Not completely sure
the reasoning behind the original table layout.
Håvard
_______________________________________________
Emc-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-developers