I use dev master branch and use remap for M6. When I load m78_test.ngc,
I get an error:
Near line 0 of /home/cnc/linuxcnc/nc_files/m78_test.ngc:
M7x: restore_settings failed executing: 'F1.0 M7 M8 M48': Two m codes
used from same modal group
----------------------------
m78_test.ngc:
----------------------------
G17 G21 G40 G90
G64P0.03Q0.03
T2 M06
M7
M8
S18000 M3
G0 Z120
T6 M06
S18000 M3
M7
M8
M30
%
----------------------------
rack_change.ngc:
----------------------------
o<rack_change> sub
m5 (Stop the spindle)
#<last_x> = #5420
#<last_y> = #5421
m73 (auto-restore modal settings on return)
M50 P0 (disable feed override)
g21 g90 (use millimeters for length units, absolute distance mode)
g49
g53 g0 Z #<_ini[toolchange]z_safe>
m9 (turn off cyclone, raise dust cover)
...
------------------------------------------------------------------------------