I use dev master branch and use remap for M6. When I load m78_test.ngc, 
I get an error:
Near line 0 of /home/cnc/linuxcnc/nc_files/m78_test.ngc:
M7x: restore_settings failed executing: 'F1.0 M7 M8 M48': Two m codes 
used from same modal group

----------------------------
m78_test.ngc:
----------------------------
G17 G21 G40 G90
G64P0.03Q0.03
T2 M06
M7
M8
S18000 M3
G0  Z120
T6 M06
S18000 M3
M7
M8
M30
%

----------------------------
rack_change.ngc:
----------------------------
o<rack_change> sub
     m5 (Stop the spindle)
     #<last_x> = #5420
     #<last_y> = #5421

     m73 (auto-restore modal settings on return)

     M50 P0 (disable feed override)

     g21 g90 (use millimeters for length units, absolute distance mode)
     g49
     g53 g0 Z #<_ini[toolchange]z_safe>
     m9 (turn off cyclone, raise dust cover)
...


------------------------------------------------------------------------------
How ServiceNow helps IT people transform IT departments:
1. Consolidate legacy IT systems to a single system of record for IT
2. Standardize and globalize service processes across IT
3. Implement zero-touch automation to replace manual, redundant tasks
http://pubads.g.doubleclick.net/gampad/clk?id=51271111&iu=/4140/ostg.clktrk
_______________________________________________
Emc-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-developers

Reply via email to