--- John Kasunich <[EMAIL PROTECTED]> wrote:

> Stephen Wille Padnos wrote:
> 
> >> # connect index pulses to motion controller
> >> # do these when index pulsing is figured out
> >> net Xindex axis.0.index-enable ppmc.0.encoder.00.index-enable
> >> net Xindex axis.1.index-enable ppmc.0.encoder.01.index-enable
> >> net Xindex axis.2.index-enable ppmc.0.encoder.02.index-enable
> >>  
> >>
> > It would probably be helpful to name these Xindex, Yindex, and
> Zindex ...
> 
> Yep.
> 
> The above lines create a single signal Xindex, which is connected
> to all three motion controller axes, and all three encoders.  So
> when ANY axis gets an index pulse, index enable is reset for ALL
> axes.
> 
> When you connect things in peculiar ways, you get peculiar
> results.
> 

Shouldn't this cause an error?!

> Regards,
> 
> John Kasunich
> 

Mark


       