--- John Kasunich <[EMAIL PROTECTED]> wrote: > Stephen Wille Padnos wrote: > > >> # connect index pulses to motion controller > >> # do these when index pulsing is figured out > >> net Xindex axis.0.index-enable ppmc.0.encoder.00.index-enable > >> net Xindex axis.1.index-enable ppmc.0.encoder.01.index-enable > >> net Xindex axis.2.index-enable ppmc.0.encoder.02.index-enable > >> > >> > > It would probably be helpful to name these Xindex, Yindex, and > Zindex ... > > Yep. > > The above lines create a single signal Xindex, which is connected > to all three motion controller axes, and all three encoders. So > when ANY axis gets an index pulse, index enable is reset for ALL > axes. > > When you connect things in peculiar ways, you get peculiar > results. >
Shouldn't this cause an error?! > Regards, > > John Kasunich > Mark ____________________________________________________________________________________Get the free Yahoo! toolbar and rest assured with the added security of spyware protection. http://new.toolbar.yahoo.com/toolbar/features/norton/index.php ------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users