2014-02-22 15:52 GMT+01:00 Peter C. Wallace <p...@mesanet.com>:
>
>
> for sinking inputs (like 7I70,7I76,7i77,7I84 field inputs) The best is NC
> PNP
> type. These will fail open (= limit) with short to ground or open wire
> faults
>
> Peter Wallace
> Mesa Electronics
>

Dammit, I've already ordered NPN NC, should have checked the spec PDF...
Ah well, I'll order a another set then...

/Sven
------------------------------------------------------------------------------