On Wed, Jan 12, 2011 at 12:03:03PM +0300, Lev Serebryakov wrote: > Hello, Pyun. > You wrote 12 января 2011 г., 1:45:26: > > > > That had been supported for long time. Just remove full-duplex > > media option in your manual configuration. > What do you mean by this? Without this media options it will be > 100Mbit half-duplex when switch port want 100Mbit full-duplex. With
Because you have to rely on parallel detection the end result would be half-duplex. So switch port could be configured to 100Mbps/half-duplex and you can still use auto-negotiation. This way re(4) may be able to establish 100Mbps half-duplex. Full-duplex would be better but it seems there is no way at this moment. > this media option result is the same because refphy(4) ignores user > requests, if I understand right. > > -- > // Black Lion AKA Lev Serebryakov <l...@serebryakov.spb.ru> > _______________________________________________ freebsd-net@freebsd.org mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-net To unsubscribe, send any mail to "freebsd-net-unsubscr...@freebsd.org"