On Wed, Jan 12, 2011 at 12:03:03PM +0300, Lev Serebryakov wrote:
> Hello, Pyun.
> You wrote 12 января 2011 г., 1:45:26:
> 
> 
> > That had been supported for long time. Just remove full-duplex
> > media option in your manual configuration.
>   What do you mean by this? Without this media options it will be
>   100Mbit half-duplex when switch port want 100Mbit full-duplex. With

Because you have to rely on parallel detection the end result would
be half-duplex. So switch port could be configured to
100Mbps/half-duplex and you can still use auto-negotiation. This
way re(4) may be able to establish 100Mbps half-duplex. Full-duplex
would be better but it seems there is no way at this moment.

>   this media option result is the same because refphy(4) ignores user
>   requests, if I understand right.
> 
> -- 
> // Black Lion AKA Lev Serebryakov <l...@serebryakov.spb.ru>
> 