On Thu, May 21, 2009 at 11:47:54AM +0200, Attilio Rao wrote: > Please try the patch here: > http://www.freebsd.org/~attilio/notify.diff
As promised I checked againts 7.2-STABLE of today (cvsup ended at 15:17 CEST, GTM+2, Italy time with DST) and ... it works ! (added and removed a disk 4 times, even during a sync-in-progress) # uname -v FreeBSD 7.2-STABLE #3: Thu May 21 18:26:04 CEST 2009 ... -----[ 1st remove ]----- mpt0: External Bus Reset Detected (mpt0:vol0:1): Physical Disk Status Changed (mpt0:vol0:0): Volume Status Changed (mpt0:vol0:1): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled ) (mpt0:vol0:1): No longer configured -----[ 1st add ]----- mpt0: External Bus Reset Detected mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Domain Validation Required mpt0:vol0(mpt0:0:0): Volume Status Changed mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 71087625 of 71087625 blocks remaining (mpt0:vol0:1): Physical (mpt0:0:1:0), Pass-thru (mpt0:1:1:0) (mpt0:vol0:1): Online (mpt0:vol0:1): Status ( Out-Of-Sync ) (mpt0:vol0:1): SMART Data Received (mpt0:vol0:1): ASC 0x5d, ASCQ 0x0) mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 71076421 of 71087625 blocks remaining mpt0:vol0(mpt0:0:0): Volume Status Changed -----[ 2nd remove ]----- mpt0: External Bus Reset Detected mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled ) (mpt0:vol0:1): Physical Disk Status Changed (mpt0:vol0:1): Physical Disk Status Changed (mpt0:vol0:1): No longer configured mpt0:vol0(mpt0:0:0): Physical Disk Status Changed -----[ 2nd add ]----- mpt0: External Bus Reset Detected mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Domain Validation Required mpt0:vol0(mpt0:0:0): Volume Status Changed mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 71087625 of 71087625 blocks remaining (mpt0:vol0:1): Physical (mpt0:0:1:0), Pass-thru (mpt0:1:1:0) (mpt0:vol0:1): Online (mpt0:vol0:1): Status ( Out-Of-Sync ) (mpt0:vol0:1): SMART Data Received (mpt0:vol0:1): ASC 0x5d, ASCQ 0x0) mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 70896522 of 71087625 blocks remaining Thanks again. -- Riccardo. _______________________________________________ freebsd-stable@freebsd.org mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-stable To unsubscribe, send any mail to "freebsd-stable-unsubscr...@freebsd.org"