All,

Module HSMSOCKB is a batch COBOL module consisting of only 'EZASOKET' calls.

When is submitted it receives the following error:

'CEE3201S The system detected an operation exception (System Completion 
Code=0C1)
         From compile unit HSMSOCK at entry point HSMSOCK.'

It appears to be having an issue with 'inaccessible storage'.

Does anything need to be included with the compile/link besides SEZATCP with 
the link syslib and
004000 //SYSIN    DD *
004200  INCLUDE SYSLIB(EZACICAL)
004400  NAME HSMSOCKB(R)
With the link as well?

Thank you...

John Weber
FiTeq Inc.
Financial Technologies Powering Innovation in Payments
  30851 Agoura Road, Suite 103
  Agoura, CA 91301
 O: 818 483 4487  Fax: 818 865 8562
 Cell: 562 221 5702

Reply via email to