Paul,
A maximum of 3 threads showing outside the barrel is the legal requirement.
See AC 43.13 para 7.166 figure 7.23 (per my 1998 edition)
Cheers
Chris Gardiner

Sent from my iPad

> On Jun 25, 2017, at 6:56 PM, Paul Visk via KRnet <krnet@list.krnet.org> wrote:
> 
> I'm trying to finish up my rigging of my ailerons. I might have one cable too 
> long and one too short.  I'm looking in 43.13 and the dark web  for the 
> maximum and minimum insertion of the ends with no luck. All I see is how to 
> safety wire turnbuckles.   And no luck contacting my tech advisor who is an 
> A&PI. Does anyone know. 
> 
> Paul Visk Belleville Il.