I have to put this 2 node active/passive cluster in production very soon and I have tested the resource migration works perfectly in case of the node running the resource goes down(abruptly/forcefully).

I have always read and heard to increase msgwait and watchdog timeout when sbd is a multipath disk, but in my case
I have just created the disk via
    sbd -d /dev/mapper/mpathe create

and I have following resource for sbd
    primitive sbd_stonith stonith:external/sbd \
            op monitor interval="3000" timeout="120" start-delay="21" \
            op start interval="0" timeout="120" \
            op stop interval="0" timeout="120" \
            params sbd_device="/dev/mapper/mpathe"

as of now I am quite satisfied, but should I increase the msgwait and watchdog timeouts ?

also I am using the start-delay=21 for "op monitor interval" should I also use the start-delay=11 for "op start interval"

Please recommend

--
Regards,

Muhammad Sharfuddin
Cell: +92-3332144823 | UAN: +92(21) 111-111-142 ext: 113 | NDS.COM.PK <http://www.nds.com.pk>