On Wed, 19 Jun 2013, Benjamin Tissoires wrote:

> From: Benjamin Tissoires <benjamin.tissoi...@redhat.com>
> Date: Wed, 19 Jun 2013 17:49:05 +0200
> Subject: [PATCH] HID: input: fix false positive out of range values
> 
> Commit 6da7066906e977d42104a859c490f5f9a300488c introduced in 3.3
> "HID: ignore absolute values which don't fit between logical min and max"
> prevents some Posiflex touch screen to work because they do not provide
> logical min and max for their buttons.
> Thus, logical min and max are at 0, discarding the buttons events, and
> preventing the device to report appropriate X Y.
> 
> Adding a check on "min < max" solves the problem.
> 
> Reported-by: Jan Kandziora <j...@gmx.de>
> Signed-off-by: Benjamin Tissoires <benjamin.tissoi...@redhat.com>

Thanks. I am applying this with Jan's Tested-by: (and I am also extending 
the comnent preceeding the condition to better explain this case).

-- 
Jiri Kosina
SUSE Labs
--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to