Hi, Guennadi and Laurent

On 1/9/2015 6:47 AM, Laurent Pinchart wrote:
Hi Guennadi and Josh,

On Thursday 08 January 2015 23:37:58 Guennadi Liakhovetski wrote:
On Wed, 7 Jan 2015, Josh Wu wrote:
On 1/7/2015 6:17 AM, Guennadi Liakhovetski wrote:
On Tue, 6 Jan 2015, Josh Wu wrote:
Hi, Guennadi

After look deep into this patch, I found you miss one line that should
be changed as well.
It's In function v4l2_clk_get(), there still has one line code called
v4l2_clk_find(dev_id, id).
You need to change it to v4l2_clk_find(dev_id, NULL) as well.
Otherwise the code that many sensor used: v4l2_clk_get(&client->dev,
"mclk") cannot acquired the "mclk" clock.

After above changes, this patch works for me.
I think you're right, in fact, since we now don't store CCF-based
v4l2_clk wrappers on the list, this can be simplified even further, I'll
update the patch. Did you only test this patch or both?
I tested both patches with Atmel-isi driver. For the 2/2 patch I applied
the modification Laurent suggested.
Those patches works for me.

The only concern is in ov2640 I still need to acquired two v4l2 clocks:
    "xvclk"  that will get the xvclk CCF clock directly.
    "mclk"  that make ISI driver call his clock_start()/stop() to
    enable/disable ISI's peripheral clock.
If I only get xvclk clock, then the camera capture will be failed with a
ISI timeout error.
No, this doesn't look right to me. The camera sensor has only one clock
input, so, it should only request one clock. Where does the clock signal
to the camera come from on your system?
That's correct, the sensor driver only has one clock input, so it should just
request the xvclk clock.

If it comes from the ISI itself, you don't need to specify the clock in
the DT, since the ISI doesn't produce a clock from DT. If you do want to
have your clock consumer (ov2640) and the supplier (ISI) properly
described in DT, you'll have to teach the ISI to register a CCF clock
source, which then will be connected to from the ov2640. If you choose not
to show your clock in the DT, you can just use v4l2_clk_get(dev, "xvclk")
and it will be handled by v4l2_clk / soc-camera / isi-atmel.

If the closk to ov2640 is supplied by a separate clock source, then you
v4l2_clk_get() will connect ov2640 to it directly and soc-camera will
enable and disable it on power-on / -off as required.
The ISI has no way to supply a sensor clock, the clock is supplied by a
separate clock source.

 From your above description it looks like the clock to ov2640 is supplied
by a separate source, but atmel-isi's .clock_start() / .clock_stop()
functions still need to be called? By looking at those functions it looks
like they turn on and off clocks, supplying the ISI itself... Instead of
only turning on and off clocks, provided by the ISI to a camera sensor. If
my understanding is right, then this is a bug in atmel-isi and it has to
be fixed.
That's correct as well, the ISI driver needs to be fixed.


Thanks both of you for the details. Now I got it.
Indeed, I need fix this in atmel-isi driver not in ov2640 driver.
So I will send a new patch for this, which should move the ISI peripheral clock enable/disable() from clock_start/stop() to isi_camera_add_device/remove_device().

Best Regards,
Josh Wu

--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html