On Fri, 20 Feb 2009 20:33:08 +0300
Anton Vorontsov <[email protected]> wrote:

> From: Ben Dooks <[email protected]>
> 
> The Samsung SDHCI (and FSL eSDHC) controller block seems to fail
> to generate an INT_DATA_END after the transfer has completed and
> the bus busy state finished.
> 
> Changes in e809517f6fa5803a5a1cd56026f0e2190fc13d5c to use the
> new busy method are the cause of the behaviour change.
> 
> Signed-off-by: Ben Dooks <[email protected]>
> Signed-off-by: Anton Vorontsov <[email protected]>
> ---

Any objections to me merging this right away? It is needed for another
controller.

Rgds
-- 
     -- Pierre Ossman