Miguel Figueiredo Mascarenhas Sousa Filipe wrote: > > this is what I get on mac book pro 15.4: > [EMAIL PROTECTED]:/usr/lib# smartctl -d ata -a /dev/sda |grep Temp > 194 Temperature_Celsius 0x0022 100 100 000 Old_age > Always - 44 (Lifetime Min/Max 23/55) > > somehow, I don't believe those 100ºC ... > > any clues to what might cause this ? Your hdd has a temperature of 44°C and had a maximum temperature of 55°C. The two 100 values are SMART indicators which describe device health. Normally a value of 100 means excellent condition.
The columns from left to right: - SMART attribute id (194) - SMART attribute name (Temperature_Celsius) - SMART attribute flag (?) - SMART indicator current value (100). This normally is a relative value. - SMART indicator worst value so far (100). This normally is a relative value. - Threshold - when the indicator value is lower than this value, the hdd needs attention. Some attributes need different interpretation on different drives. My has the following attributes for temperature: 194 Temperature_Celsius 0x0022 037 055 000 Old_age Always - 37 (Lifetime Min/Max 0/19) Current and worst values indicate current and highest temperature so far on this drive. By the way - the temperature is so low, because the Mac has just been booted. - Jan. ------------------------------------------------------------------------- Using Tomcat but need to do more? Need to support web services, security? Get stuff done quickly with pre-integrated technology to make your job easier Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo http://sel.as-us.falkag.net/sel?cmd=lnk&kid=120709&bid=263057&dat=121642 _______________________________________________ Mactel-linux-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/mactel-linux-users