Hello,

I noticed that "no_comp_alerts" does not work in the following configuration:

watch HOSTGROUP
     service SVC
        interval 5m
        monitor MONITOR
        period failure: wd{mon-fri} hr{8-18}
            alert wh-file.alert
        period up: wd{mon-sun}
            no_comp_alerts
            upalert wh-file.alert


Looking in the code and logs, I found that
_no_comp_alerts_upalert_sent is never reset to zero when no alert
script is called. So upalerts are sent only once (at startup or
reset).

The following patch against mon 1.2.0 seems to correct this, by
forcing the reset as soon as possible:

--- mon.orig    2007-07-23 17:37:10.988935200 +0200
+++ mon 2007-07-23 17:38:34.916224800 +0200
@@ -666,6 +666,18 @@

        my $pref = \%{$sref->{"periods"}->{$periodlabel}};

+        #
+       # Reset no_comp_alerts counter if ALERT
+       #
+       if ($pref->{"no_comp_alerts"} &&
+           $pref->{"_no_comp_alerts_upalert_sent"} > 0 &&
+           !($flags & ($FL_UPALERT|$FL_ACKALERT|$FL_DISABLEALERT|$FL_ENABLEALER
+T))) {
+           syslog('debug',"$group/$service/$periodlabel: ALERT, no_comp_alerts
+reset");
+           $pref->{"_no_comp_alerts_upalert_sent"} = 0;
+       }
+
        #
        # skip upalerts/ackalerts not paired with down alerts
        # disable by setting "no_comp_alerts" in period section


Does it look reasonable ?

Thanks,
-- 
Nicolas