Hello community, here is the log from the commit of package mdadm for openSUSE:Factory checked in at 2014-07-12 17:14:20 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Comparing /work/SRC/openSUSE:Factory/mdadm (Old) and /work/SRC/openSUSE:Factory/.mdadm.new (New) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Package is "mdadm" Changes: -------- --- /work/SRC/openSUSE:Factory/mdadm/mdadm.changes 2014-06-18 07:50:25.000000000 +0200 +++ /work/SRC/openSUSE:Factory/.mdadm.new/mdadm.changes 2014-07-12 17:14:21.000000000 +0200 @@ -1,0 +2,13 @@ +Thu Jun 26 03:08:15 UTC 2014 - [email protected] + +- 0001-Grow-fix-removal-of-line-in-wrong-case.patch + (bnc#881530) + +------------------------------------------------------------------- +Thu Jun 26 02:54:05 UTC 2014 - [email protected] + +- add mkinitrd scripts back in. They are needed by + "guestfs" + (bnc#883873) + +------------------------------------------------------------------- New: ---- 0001-Grow-fix-removal-of-line-in-wrong-case.patch mkinitrd-boot.sh mkinitrd-setup.sh ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Other differences: ------------------ ++++++ mdadm.spec ++++++ --- /var/tmp/diff_new_pack.tL4vnE/_old 2014-07-12 17:14:22.000000000 +0200 +++ /var/tmp/diff_new_pack.tL4vnE/_new 2014-07-12 17:14:22.000000000 +0200 @@ -37,9 +37,13 @@ Source: https://www.kernel.org/pub/linux/utils/raid/mdadm/%{name}-%{version}.tar.xz Source1: Software-RAID.HOWTO.tar.bz2 Source2: sysconfig.mdadm +Source5: mkinitrd-setup.sh +Source6: mkinitrd-boot.sh Source7: mdadm.cron # PATCH-FIX-UPSTREAM 0001-Makefile-install-mdadm-grow-continue-.service.patch [email protected] Patch1: 0001-Makefile-install-mdadm-grow-continue-.service.patch +# PATCH-FIX-UPSTREAM 0001-Grow-fix-removal-of-line-in-wrong-case.patch bnc#881530 [email protected] +Patch2: 0001-Grow-fix-removal-of-line-in-wrong-case.patch %define _udevdir %(pkg-config --variable=udevdir udev) %define _systemdshutdowndir %{_unitdir}/../system-shutdown @@ -52,6 +56,7 @@ %prep %setup -q -a1 %patch1 -p1 +%patch2 -p1 %build make %{?_smp_mflags} CC="%__cc" CXFLAGS="$RPM_OPT_FLAGS -Wno-error" SUSE=yes @@ -64,6 +69,9 @@ rm -rf %{buildroot}/lib/udev install -d %{buildroot}%{_var}/adm/fillup-templates install -d %{buildroot}{%{_sbindir} +install -d %{buildroot}/lib/mkinitrd/scripts +install -m 755 %{S:5} %{buildroot}/lib/mkinitrd/scripts/setup-md.sh +install -m 755 %{S:6} %{buildroot}/lib/mkinitrd/scripts/boot-md.sh install -d %{buildroot}/etc/cron.daily install -m 755 %{S:7} %{buildroot}/etc/cron.daily/mdadm install -m 644 %{S:2} %{buildroot}%{_var}/adm/fillup-templates/ @@ -90,6 +98,10 @@ %doc %{_mandir}/man?/* /sbin/* %{_var}/adm/fillup-templates/sysconfig.mdadm +%dir /lib/mkinitrd +%dir /lib/mkinitrd/scripts +/lib/mkinitrd/scripts/setup-md.sh +/lib/mkinitrd/scripts/boot-md.sh %{_udevdir}/rules.d/63-md-raid-arrays.rules %{_udevdir}/rules.d/64-md-raid-assembly.rules %dir /etc/cron.daily ++++++ 0001-Grow-fix-removal-of-line-in-wrong-case.patch ++++++ >From e339dba2a1744dc6860a58e286ded39fc993c2db Mon Sep 17 00:00:00 2001 From: Pawel Baldysiak <[email protected]> Date: Wed, 11 Jun 2014 15:18:44 +0000 Subject: [PATCH] Grow: fix removal of line in wrong case Commit 18d9bcfa33939cee345d4d7735bc6081bcc409c8 removed wrong line (in case RAID0->RAID4). This patch corrects this mistake (line should be removed in case RAID4->RAID4). Signed-off-by: Pawel Baldysiak <[email protected]> Signed-off-by: NeilBrown <[email protected]> --- Grow.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Grow.c b/Grow.c index 12730e26fd19..a2f4f1428787 100644 --- a/Grow.c +++ b/Grow.c @@ -1324,6 +1324,7 @@ char *analyse_change(char *devname, struct mdinfo *info, struct reshape *re) switch (re->level) { case 4: + re->before.layout = 0; re->after.layout = 0; break; case 5: @@ -1339,7 +1340,6 @@ char *analyse_change(char *devname, struct mdinfo *info, struct reshape *re) switch (re->level) { case 4: - re->before.layout = 0; re->after.layout = 0; break; case 5: -- 2.0.0 ++++++ mkinitrd-boot.sh ++++++ #!/bin/bash #%stage: boot #%depends: start #%programs: /sbin/mdadm /sbin/mdmon #%modules: raid0 raid1 raid10 raid456 #%if: -n "$need_mdadm" # ##### MD (Software-)Raid ## ## This only sets the 'start_ro' module parameter to ensure ## arrays don't start resync until after the first write. ## All array assembly is performed by udev -> "mdadm -I" ## ## Command line parameters ## ----------------------- ## ## need_mdadm=1 use MD raid ## # load the necessary module before we initialize the raid system load_modules #check_for_device uses $md_major #we depend on 'start' to ensure /proc/devices exists md_major=$(sed -ne 's/\s*\([0-9]\+\)\s*md$/\1/p' /proc/devices) # Always start md devices read/only. They will get set to rw as soon # as the first write occurs. This way we can guarantee that no # restore occurs before resume. if [ -f /sys/module/md_mod/parameters/start_ro ]; then echo 1 > /sys/module/md_mod/parameters/start_ro fi ++++++ mkinitrd-setup.sh ++++++ #!/bin/bash # #%stage: softraid # mdblockdev= # Full mdadm.conf generated by mdadm. # Contains all created MD RAIDs mdadm_conf= cont_list= md_devs= declare -A md_conf # blockdev contains real devices (/dev/X) for root, resume, journal, dumb for bd in $blockdev ; do is_part_dev=false case $bd in /dev/md[_0-9]*p[0-9]* ) # Partitionable MD RAID. This is partition on RAID. Get the RAID bd=${bd%%p[0-9]*} is_part_dev=true ;; /dev/md[0-9_]*) ;; *) mdblockdev="$mdblockdev $bd" continue ;; esac # Check if this device is already added (possible for partitionable). md_dev=`mdadm -D --export $bd | sed -n -e 's/^MD_DEVNAME=//p'` if [ -z "$md_dev" ]; then md_dev=${bd##/dev/} else bd="/dev/md/$md_dev" fi dup_found=false for dup in $md_devs; do if [ x"$dup" = x"$md_dev" ]; then dup_found=true break fi done if $dup_found; then if ! $is_part_dev; then echo "setup-md.sh: $md_dev found multiple times" >&2 fi continue fi mdconf=$(mdadm -Db "$bd") if test -z "$mdconf"; then mdblockdev="$mdblockdev $bd" continue fi md_tmpblockdev=$(mdadm -Dbv $bd | sed -n "1D;s/,/ /g;s/^ *devices=//p") mdblockdev="$mdblockdev $md_tmpblockdev" md_devs="$md_devs $md_dev" container=$(echo "$mdconf" | sed -rn 's/.* container=([^ ]*) .*/\1/p') for cnt in $cont_list; do if [ x"$container" = x"$cnt" ]; then container= break fi done case "$container" in "") ;; /dev/*) mdconf="$(mdadm -Db "$container")\\n$mdconf" cont_list="$cont_list $container" ;; [0-9a-f]*[0-9a-f]) if test -z "$mdadm_conf"; then mdadm_conf=$(mdadm --examine --brief --scan) fi mdconf="$(echo "$mdadm_conf" | grep "UUID=$container")\\n$mdconf" cont_list="$cont_list $container" ;; *) echo "unrecognized container for $md_dev: $container" ;; esac # If /etc/mdadm.conf contains a different name for this # array, then use that. md_uuid=`echo $mdconf | sed -n -e 's/.* UUID=\([0-9a-f:]*\).*/\1/p'` if [ -f /etc/mdadm.conf -a -n "$md_uuid" ]; then md_devname=`sed -n -e 's,^ARRAY */dev/\([^ ]*\) .*[Uu][Uu][Ii][Dd]='$md_uuid'.*,\1,p' /etc/mdadm.conf` if [ -n "$md_devname" ]; then mdconf=`echo $mdconf | sed -e 's,^ARRAY /dev/\([^ ]*\),ARRAY /dev/'$md_devname','` fi fi md_conf["$md_dev"]="$mdconf" root_md=1 done # Any 'md' device is replaced by it's component disks. blockdev="$mdblockdev" if [ -n "$root_md" ] ; then need_mdadm=1 echo "AUTO -all" > $tmp_mnt/etc/mdadm.conf for md in $md_devs; do echo -e "${md_conf["$md"]}" >> $tmp_mnt/etc/mdadm.conf done fi if [ "x$need_mdadm" = "x1" ] ; then for rule in \ 63-md-raid-arrays.rules \ 64-md-raid-assembly.rules; do if [ -f /usr/lib/udev/rules.d/$rule ]; then cp /usr/lib/udev/rules.d/$rule $tmp_mnt/usr/lib/udev/rules.d elif [ -f /lib/udev/rules.d/$rule ]; then cp /lib/udev/rules.d/$rule $tmp_mnt/lib/udev/rules.d fi done fi save_var need_mdadm -- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]