Hi all,

I have several pressure sensors connected to a DS2450 each. Now I'm 
monitoring the measured pressure and sometimes I see pressure jumps. 
Before each pressure jump, the sensor stucks and then jumps to a higher 
value.
To ensure that it is not the sensor, which causes this trouble, I 
sourced the same input of the ADC with a voltage source, and measured 
voltage against the applied voltage.
There I see the same voltage jump at 2.56V. This seems to be the switch 
in the reference voltage.

Is it possible to set the reference, the ADC should use?

Cheers,

Jochen


------------------------------------------------------------------------------