On Fri, Jul 8, 2011 at 2:46 PM, Pedro Côrte-Real <[email protected]> wrote:
> have just gotten another 85ºC reading from one of the DS18S20 in one of the
> Humidity/Temp hobby board sensors.

That 85C reading was exactly on startup. It seems that what is
happening is that sometimes the first reading from the 18S20 is an 85
and then it works fine.