Hi Lincoln,

I checked our MS SQL 7.0 Accounting table for the data types.  They are
32-bit, but I don't know how to check if they're "unsigned".  Do you
know where I can find that information?

The only fields that are integers are:
Acct-Session-Time
Acct-Delay-Time
Acct-Input-Octets
Acct-Output-Octets
NAS-Port

Thanks,
Janet

Lincoln Broomhall wrote:
> 
> Is your integer field 32-bit unsigned ? That is what NAS's are typically.
> 
> -----Original Message-----
> From: Janet N del Mundo [mailto:[EMAIL PROTECTED]]
> Sent: Thursday, 25 January 2001 12:24 PM
> To: [EMAIL PROTECTED]
> Subject: (RADIATOR) Arithmetic overflow error...
> 
> Hi,
> 
> I recently installed iPass on our network and I noticed that some Stop
> records are not being inserted in the accounting table.  In the logs, it
> has the error:
> 
> ---------------------------------------------------------------------------
> [OpenLink][ODBC][SQL Server]Arithmetic overflow error converting numeric
> to data type int
> ---------------------------------------------------------------------------
> 
> I've looked at my radius.cfg and I compared all the integer fields to
> the data that's trying to be inserted into those fields.  The only
> integer field that has no data being inserted is the Acct-Delay-Time.
> 
> I don't know why these Stop records are not being recorded.  Anybody
> have a clue?
> 
> cfg file
> --------------------------------------------------------------------
>         AccountingTable ACCOUNTING
> 
>         AcctColumnDef   IDENTIFIER,User-Name
>         AcctColumnDef   TIME_STAMP,Timestamp,formatted-date,'%m-%d-%Y
> %H:%M:%S'
> ->        AcctColumnDef   DURATION,Acct-Session-Time,integer
>         AcctColumnDef   ACCTSTATUSTYPE,Acct-Status-Type
> ->        AcctColumnDef   ACCTDELAYTIME,Acct-Delay-Time,integer
> ->        AcctColumnDef   ACCTINPUTOCTETS,Acct-Input-Octets,integer
> ->        AcctColumnDef   ACCTOUTPUTOCTETS,Acct-Output-Octets,integer
>         AcctColumnDef   ACCTSESSIONID,Acct-Session-Id
>         AcctColumnDef   ACCTTERMINATECAUSE,Acct-Terminate-Cause
>         AcctColumnDef   NASIDENTIFIER,NAS-IP-Address
> ->        AcctColumnDef   NASPORT,NAS-Port,integer
>         AcctColumnDef   FRAMEDIPADDRESS,Framed-IP-Address
>         AcctColumnDef   CONNECTSPEED,Connect-Info
>         AcctColumnDef   CONNECTSPEED,USR-Connect-Speed
>         AcctColumnDef   CALLERID,Calling-Station-Id
>         AcctColumnDef   POPID,Called-Station-Id
> 
> logfile
> --------------------------------------------------------------------
> Wed Jan 24 20:19:09 2001: ERR: do failed for 'insert into ACCOUNTING
>                 (IDENTIFIER, TIME_STAMP, DURATION, ACCTSTATUSTYPE,
> ACCTINPUTOCTETS, ACCTOUTPUTOCTETS, ACCTSESSIONID, NASIDENTIFIER,
> NASPORT, FRAMEDIPADDRESS, POPID)
>                 values
>                 ('lcf', '01-24-2001 20:19:08', 153, 'Stop', 471793664,
> 2636644608, '327172759', '210.253.96.17', 21606, '210.253.98.190', '')':
> [OpenLink][ODBC][SQL Server]Arithmetic overflow error converting numeric
> to data type int. (SQL-S1000)(DBD: st_execute/SQLExecute err=-1)
> 
> I'd appreciate any help or hints!!!
> Thank you,
> Janet
> 
> _____________________________________________________
> Janet del Mundo
> Internet Administrator, Startec Global Communications
> 135 Chalan Santo Papa   Agana, Guam  96910
> Email: [EMAIL PROTECTED]
> 
> ===
> Archive at http://www.starport.net/~radiator/
> Announcements on [EMAIL PROTECTED]
> To unsubscribe, email '[EMAIL PROTECTED]' with
> 'unsubscribe radiator' in the body of the message.

-- 
_____________________________________________________
Janet del Mundo 
Internet Administrator, Startec Global Communications
135 Chalan Santo Papa   Agana, Guam  96910
Email: [EMAIL PROTECTED]
Phone: (671) 475-6879
Fax  : (671) 477-6054

===
Archive at http://www.starport.net/~radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.