Hi all On Dec 14, 2010, at 4:17 PM, Markus wrote:
> Hi *, > > I performed the automated tests on the ML605. 64 of 65 tests succeeded, but > one test failed (mutex_test_posix). > > Thus, I run the failed test some more times, in total 7 times. > - 3 runs: > went fine > - 3 runs: > the mutex was not locked in-between by the hw thread 1 of 10 times > - 1 run: > the mutex was not locked in-between by the hw thread 2 of 10 times > > The debug output of the last run with 2 unsuccessful mutex_lock's is > attached. Interestingly, the delegate receives the command to lock a mutex > before the mutex is locked by the software, which should not happen. I could > not reproduce this error for the ecos API, which is a bit odd. > > It would be interesting to know, if anyone can reproduce this failure. I finally managed to do the tests. The exec_mutex_posix test also failed in my setup. My statistics are: Success: 6 runs 1 failure: 4 runs failure: mutex lock and release by hwthread: too early (occurrence: once but at different stages) All the other tests were ok. Cheers, Ariane _______________________________________________ Reconos-devel_lists.reconos.de mailing list reconos-devel@lists.reconos.de https://ml01.ispgateway.de/mailman/listinfo/reconos-devel_lists.reconos.de