Hi all

On Dec 14, 2010, at 4:17 PM, Markus wrote:

> Hi *,
> 
> I performed the automated tests on the ML605. 64 of 65 tests succeeded, but 
> one test failed (mutex_test_posix). 
> 
> Thus, I run the failed test some more times, in total 7 times.
>   - 3 runs: 
>       went fine
>   - 3 runs: 
>       the mutex was not locked in-between by the hw thread 1 of 10 times
>   - 1 run: 
>       the mutex was not locked in-between by the hw thread 2 of 10 times
> 
> The debug output of the last run with 2 unsuccessful mutex_lock's is 
> attached. Interestingly, the delegate receives the command to lock a mutex 
> before the mutex is locked by the software, which should not happen. I could 
> not reproduce this error for the ecos API, which is a bit odd.
> 
> It would be interesting to know, if anyone can reproduce this failure.

I finally managed to do the tests.  The exec_mutex_posix test also failed in my 
setup.
My statistics are:
Success: 6 runs
1 failure: 4 runs

failure:
mutex lock and release by hwthread: too early
(occurrence: once but at different stages)

All the other tests were ok.

Cheers,
Ariane

_______________________________________________
Reconos-devel_lists.reconos.de mailing list
reconos-devel@lists.reconos.de
https://ml01.ispgateway.de/mailman/listinfo/reconos-devel_lists.reconos.de

Antwort per Email an