Sounds like someone has been watching The Enforcer....Mr Eastwood.....every man has got to know his limitations?
Soory ....could not resist!! D On 30/07/2010 22:35:35, Jeff DePolo (j...@broadsci.com) wrote: > > I wonder how many of the -53 naysayers have or have used a Cushman > > CE-3? LOL! The folks that have looked at the output of one of > > these on > > a spectrum analyzer will get it. > > > > K > > Where I come from, we call that a comb generator, not a signal generator... > > > Ya gotta know the limitations of your test equipment. I recently went > several rounds via telephone with a friend of mine who was trying to > troubleshoot an apparent desense problem on the bench involving a Mastr > II > and a 6-cavity DB Products duplexer that I had tuned up for him on the VNA. > > Long story short, it turned out that when he was doing the desense test > using his service monitor (R2600?) as the dummy load and signal source > simultaneously that the sig gen would go spurious and result in apparent > desense. When he finally did a lossy tee test using an external dummy > load, > no desense, and likewise when hooked up to the antenna at the site, > no > desense. > > --- Jeff WN3A > > > > ------------------------------------ > > > > Yahoo! Groups Links >