[ccp4bb] Beamtime at SLS X06SA - deadline: 15th Feb

2009-02-13 Thread TOMIZAKI, Takashi

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AT SLS FROM MAY TO AUGUST 2008
=

- PILATUS 6M pixel detector  available for user operation at High 
Resolution Diffractometer.
Continuous, fine phi-sliced data acquisition (12.5 frames per second) 
with 20 bit dynamic range,
see http://pilatus.web.psi.ch/  or www.dectris.com 
http://www.dectris.com/ for further information


- mar225 CCD installed at Micro-Diffractometer MD2. This 
MAD-compatible diffractometer allows 
for data collection with a focussed beam size of 25 x 5 micrometers, and 
down to 10 x 5 micrometer 
using an apertures.


- SLS is able to provide support for travel and accomodation for two 
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent 
highlights: http://sls.web.psi.ch/view.php/beamlines/px/research/index.html


   PROPOSAL SUBMISSION DEADLINE: SUNDAY, 15TH FEBRUARY

You need send proposals both X06SA(PX1) and X06DA(PX3) individually if 
you would like to have

beamtimes on both beamlines.

For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html

Looking forward to seeing you at SLS,

TOMIZAKI, Takashi


[ccp4bb] Beamtime at SLS X06SA

2008-10-03 Thread Clemens Schulze-Briese

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AT SLS FROM JANUARY TO APRIL 2008
=

- PILATUS 6M pixel detector  available for user operation at High  
Resolution Diffractometer.
Continuous, fine phi-sliced data acquisition (12.5 frames per second)  
with 20 bit dynamic range,
see http://pilatus.web.psi.ch/  or www.dectris.com for further  
information


- mar225 CCD installed at Micro-Diffractometer MD2. This MAD- 
compatible diffractometer allows
for data collection with a focussed beam size of 25 x 5 micrometers,  
and down to 10 x 5 micrometer

using an apertures.

- SPINE compatible CATS sample changer installed at HRD-diffractometer.

- ACTOR sample changer operational at the Micro-Diffractometer.

- SLS is able to provide support for travel and accomodation for two  
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent highlights: 
http://sls.web.psi.ch/view.php/beamlines/px/research/index.html

PROPOSAL SUBMISSION DEADLINE: Wednesday, October 15th 2008 .

For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html


Looking forward to seeing you at SLS,

Clemens Schulze-Briese




Dr. Clemens Schulze-Briese - [EMAIL PROTECTED]
---
 Swiss Light Source at Paul Scherrer Institut
  CH-5232 Villigen PSI - http://sls.web.psi.ch
Phone +41 56 310 4533 - Fax -5292 - Secretary -3178



[ccp4bb] Beamtime at SLS X06SA

2008-06-09 Thread Clemens Schulze-Briese

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AT SLS FROM SEPTEMBER- DEC 2008
=

- PILATUS 6M pixel detector  available for user operation at High 
Resolution Diffractometer.
Continuous data acquisition (12.5 frames per second) with 20 bit dynamic 
range, see

http://pilatus.web.psi.ch/  or www.dectris.com  as well as
http://www.nature.com/nature/journal/v452/n7185/full/nature06717.html
for further information

- CATS sample changer available at the High Resolution Diffractometer, cf.
http://www.irelec.fr/en/produit.asp?idproduit=38

- Detector upgrade to mar225 CCD on Micro-Diffractometer MD2. This 
MAD-compatible
diffractometer allows for data collection with a beam size of 15 x 5 
micrometers. ACTOR

sample changer available at the MD2.

- SLS is able to provide support for travel and accomodation for two 
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent highlights: 
http://sls.web.psi.ch/view.php/beamlines/px/research/index.html


PROPOSAL SUBMISSION DEADLINE: Sunday, June 15th 2008.

For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html 




Looking forward to seeing you at SLS,

Clemens Schulze-Briese

--
Dr. Clemens Schulze-Briese - [EMAIL PROTECTED]
---
Swiss Light Source at Paul Scherrer Institut
 CH-5232 Villigen PSI - http://sls.web.psi.ch
Phone +41 56 310 4533 - Fax -5292 - Secretary -3178


[ccp4bb] BEAMTIME AT SLS X06SA and X06DA

2008-02-08 Thread Clemens Schulze-Briese

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AND THE SUPERBENDING MAGNET 
   BEAMLINE  X06DA AT SLS FROM  MAY  -  AUGUST 2008

=

- PILATUS 6M pixel detector  available for user operation at High 
Resolution Diffractometer.
Continuous data acquisition (10 frames per second) with 20 bit dynamic 
range,

see http://pilatus.web.psi.ch/  or www.dectris.com for further information

- Detector upgrade to mar225 CCD on Micro-Diffractometer MD2. This 
MAD-compatible

diffractometer allows for data collection with a beam size of 5 micrometers.

-  NEW : the superbend beamline X06DA. Mini-hutch design for efficient 
sample mounting.

CATS sample changer in preparation. For further information:
http://sls.web.psi.ch/view.php/beamlines/px3/index.html

- SLS is able to provide support for travel and accomodation for two 
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent highlights: 
http://sls.web.psi.ch/view.php/beamlines/px/research/index.html


PROPOSAL SUBMISSION DEADLINE: Friday, Feb 15th 2008 (midnight)

For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html


Looking forward to seeing you at SLS,

Clemens Schulze-Briese

--
Dr. Clemens Schulze-Briese - [EMAIL PROTECTED]
---
   Swiss Light Source at Paul Scherrer Institut
CH-5232 Villigen PSI - http://sls.web.psi.ch
Phone +41 56 310 4533 - Fax -5292 - Secretary -3178


[ccp4bb] Beamtime at SLS X06SA

2007-10-05 Thread Clemens Schulze-Briese

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AT SLS FROM  JANUARY-APRIL 2008
=

- PILATUS 6M pixel detector  available for user operation at High 
Resolution Diffractometer.
Continuous data acquisition (10 frames per second) with 20 bit dynamic 
range,

see http://pilatus.web.psi.ch/  or www.dectris.com for further information

- CATS sample changer (http://www.irelec.fr/en/produit.asp?idproduit=38) 
to be installed in

April on HR - diffractometer

- Detector upgrade to mar225 CCD on Micro-Diffractometer MD2. This 
MAD-compatible
diffractometer allows for data collection with a beam size down to 5 
micrometers.


- ACTOR sample changer operational on the Micro-Diffractometer.
Adaptor for use of SPINE pucks in preparation.

- SLS is able to provide support for travel and accomodation for two 
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent highlights: 
http://sls.web.psi.ch/view.php/beamlines/px/research/index.html


PROPOSAL SUBMISSION DEADLINE: Monday, October 15th 2007.

For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html 




Looking forward to seeing you at SLS,

Clemens Schulze-Briese

--
Dr. Clemens Schulze-Briese - [EMAIL PROTECTED]
---
Swiss Light Source at Paul Scherrer Institut
 CH-5232 Villigen PSI - http://sls.web.psi.ch
Phone +41 56 310 4533 - Fax -5292 - Secretary -3178


[ccp4bb] Beamtime at SLS X06SA

2007-06-13 Thread Clemens Schulze-Briese

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AT SLS FROM SEPTEMBER- DEC 2007
=

- PILATUS 6M pixel detector  available for user operation at High 
Resolution Diffractometer.
 Continuous data acquisition (10 frames per second) with 20 bit dynamic 
range,

 see http://pilatus.web.psi.ch/  or www.dectris.com for further information

- Detector upgrade to mar225 CCD on Micro-Diffractometer MD2. This 
MAD-compatible
diffractometer allows for data collection with a beam size of 15 x 5 
micrometers.


- ACTOR sample changer operational on the Micro-Diffractometer.
 Adaptor for use of SPINE pucks in preparation.

- SLS is able to provide support for travel and accomodation for two 
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent highlights: 
http://sls.web.psi.ch/view.php/beamlines/px/research/index.html


 PROPOSAL SUBMISSION DEADLINE: Friday, June 15th 2007.

For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html 




Looking forward to seeing you at SLS,

Clemens Schulze-Briese

--
Dr. Clemens Schulze-Briese - [EMAIL PROTECTED]
---
Swiss Light Source at Paul Scherrer Institut
 CH-5232 Villigen PSI - http://sls.web.psi.ch
Phone +41 56 310 4533 - Fax -5292 - Secretary -3178


[ccp4bb] Beamtime at SLS X06SA

2007-02-13 Thread Clemens Schulze-Briese

=
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY
AT THE UNDULATOR BEAMLINE X06SA AT SLS FROM MAY  -  AUGUST  2007
=

- PILATUS 6M pixel detector will become available for  user operation in 
May 2007 at the

High Resolution Diffractometer; http://pilatus.web.psi.ch/

- Detector upgrade to mar225 CCD on Micro-Diffractometer MD2. This 
MAD-compatible
diffractometer allows for data collection with a beam size of 15 x 5 
micrometers.


- A robotic sample changer is currently in the commissioning phase and 
will be available on

the Micro-Diffractometer.

- SLS is able to provide support for travel and accomodation for two 
users per trip:

http://sls.web.psi.ch/view.php/users/experiments/eusupport/index.html

- For recent highlights: 
http://sls.web.psi.ch/view.php/beamlines/px/research/index.html



  PROPOSAL SUBMISSION DEADLINE: Wednesday, February 15th 2007.


For further information and / or proposal submission:
http://sls.web.psi.ch/view.php/users/experiments/proposals/opencalls/PX/index.html 




Looking forward to seeing you at SLS,

Clemens Schulze-Briese

--
Dr. Clemens Schulze-Briese - [EMAIL PROTECTED]
---
Swiss Light Source at Paul Scherrer Institut
 CH-5232 Villigen PSI - http://sls.web.psi.ch
Phone +41 56 310 4533 - Fax -5292 - Secretary -3178