[Asterisk-Users] Provisioned, Down, Active, but D-channel seems to be fine

2005-09-05 Thread steve
Hi, I'm seeing rather odd behaviour on a new box with TE110P card. I'm running the TE110P span with ccs,hdb3,crc4 in pri_net, connected to a second machine with a TE410P in pri_cpe. The span is idle. I'm using pri intense debug span 1 and can see the RRs going back and forth. So - things

Re: [Asterisk-Users] Provisioned, Down, Active, but D-channel seems to be fine

2005-09-05 Thread Kevin P. Fleming
[EMAIL PROTECTED] wrote: But, pri show span 1 shows the span now as Provisioned, Down, Active. But all along we are exchanging RRs (receive ready) with the remote system. The telco has turned your circuit 'administratively down' so their operator console would stop getting spammed with

Re: [Asterisk-Users] Provisioned, Down, Active, but D-channel seems to be fine

2005-09-05 Thread steve
On Mon, 5 Sep 2005, Kevin P. Fleming wrote: [EMAIL PROTECTED] wrote: But, pri show span 1 shows the span now as Provisioned, Down, Active. But all along we are exchanging RRs (receive ready) with the remote system. The telco has turned your circuit 'administratively down' so

Re: [Asterisk-Users] Provisioned, Down, Active, but D-channel seems to be fine

2005-09-05 Thread Kevin P. Fleming
[EMAIL PROTECTED] wrote: Thanks for taking the trouble to actually read my post. Doh! Blame it on my weekend laziness :-) The other end of the circuit is another Asterisk box. Hmm... I have never seen that happen before, Asterisk is pretty aggressive about bringing the D-channel up as