With a 6513-E would you be able run it with:
2xSUP720-3BXLs
10xWS-6748(/w DFCs)
1x WS-6708?
I don't need the 10/100/1000 ports to be line rate either.
I know in the regular 6513 you can only put the higher-end cards in the last
few slots, but I can't really find out if that is still true on
: 17 August, 2011 11:28
To: cisco-nsp
Subject: [c-nsp] A bit of 6513-E confusion
With a 6513-E would you be able run it with:
2xSUP720-3BXLs
10xWS-6748(/w DFCs)
1x WS-6708?
I don't need the 10/100/1000 ports to be line rate either.
I know in the regular 6513 you can only put the higher-end cards
You need the sup2t to be able to get dual fabric connections in the upper
slots I believe.
On Aug 17, 2011 2:58 PM, Drew Weaver drew.wea...@thenap.com wrote:
With a 6513-E would you be able run it with:
2xSUP720-3BXLs
10xWS-6748(/w DFCs)
1x WS-6708?
I don't need the 10/100/1000 ports to be
[mailto:cisco-nsp-boun...@puck.nether.net] On Behalf Of Drew Weaver
Sent: Wednesday, August 17, 2011 2:28 PM
To: cisco-nsp
Subject: [c-nsp] A bit of 6513-E confusion
With a 6513-E would you be able run it with:
2xSUP720-3BXLs
10xWS-6748(/w DFCs)
1x WS-6708?
I don't need the 10/100/1000 ports to be line rate
Drew said:
With a 6513-E would you be able run it with:
2xSUP720-3BXLs
10xWS-6748(/w DFCs)
1x WS-6708?
I don't think so. The fabric limitation with Sup720 in a 13-slot chassis isn't
so much a chassis problem as it is a supervisor fabric problem.
The Sup720 just doesn't have enough fabric
Hi,
On Wed, Aug 17, 2011 at 02:27:50PM -0400, Drew Weaver wrote:
With a 6513-E would you be able run it with:
2xSUP720-3BXLs
10xWS-6748(/w DFCs)
1x WS-6708?
As far as I understand, you need a Sup-2T to get dual-fabric connections
to all the slots. So the answer would be no.
I know in