Mistake changing seria number

2010-04-20 Thread Gonzalo Odiard
One of the XOs 1.5 here in La Rioja have the serial number with lower case letters SHC00500ad0, this machine can't be activated. We tried to change the tag, but made a mistake and used delete-tag and not change-tag, and the machine has security enabled. The machine doesn't have serial number now,

Re: Mistake changing seria number

2010-04-20 Thread Mitch Bradley
Your only option at this point is to replace the SPI FLASH part. Gonzalo Odiard wrote: One of the XOs 1.5 here in La Rioja have the serial number with lower case letters SHC00500ad0, this machine can't be activated. We tried to change the tag, but made a mistake and used delete-tag and not

Re: Mistake changing seria number

2010-04-20 Thread Mitch Bradley
Well, actually, there is one other option - it is possible to use one XO-1.5 to reprogram the SPI FLASH inside another. It requires that you solder header connectors to both machines and connect them with a ribbon cable. I don't think that there is a writeup for how to do it. Mitch Bradley