There was a recent discussion on this list about a six-band limit on the number 
of bands (out of the nine HF bands which may be assigned) for which the K1 MPU 
would retain LCD frequency calibration data.

Wayne has provided the following clarification:

> The calibration table has one entry for each of the bands 
> from 160-10 m. You'd be able to maintain separate calibration 
> on all of your modules, on all bands.

There is thus no need to worry about losing any band cal data should you come 
up with different filter board bands numbering more than six.

73,
Mike / KK5F