Hello
I assembled a W2 wattmeter last december, but I had to spend a couple of
weeks in a clinic, and when back home, I tested it, but it did work as it
ought to !
When power on, no problem ; when tappingrange, the 2 watt led never
lights up. The others do normally.
If I apply RF via the K3,
et bonne chance!
73 de Glenn ON4WIX
- Original Message -
From: f9oj.7 f9o...@wanadoo.fr
To: Elecraft elecraft@mailman.qth.net
Sent: Wednesday, January 13, 2010 2:44 PM
Subject: [Elecraft] do I miss something...?
Hello
I assembled a W2 wattmeter last december, but I had to spend
Hi Jacques,
Which sensor do you have? The 2W range is not available with the 2KW sensor.
The flashing SWR LED's indicates a SWR Alarm state. This happens when the W2's
SWR Alarm is turned on and the SWR is excessively high. You can use the W2
Utility or the W2 Interface software to turn the
On Wed, 13 Jan 2010 14:44:03 +0100, f9oj.7 f9o...@wanadoo.fr
wrote:
Hello
I assembled a W2 wattmeter last december, but I had to spend a couple of
weeks in a clinic, and when back home, I tested it, but it did work as it
ought to !
When power on, no problem ; when tappingrange, the 2 watt led
4 matches