Re: [Emc-developers] Change in feed override during machine run causes 1 milisecond stalls

2006-12-25 Thread Mario .
Okay, I admit some serious problems in the vesa display driver which was loaded by default. Like: if you switched between tty1 and tty2 small delay of ~5000ns could be introduced, but switching from tty1 to tty7 to graphical interface induced ~34 nanoseconds delay each time during CRT monitor

Re: [Emc-developers] Change in feed override during machine run causes 1 milisecond stalls

2006-12-25 Thread Anders Wallin
But the FEED OVERRIDE problem still remained. Jumping the slider left and right resulted in time between calls to motion controller of 0.957ms, 1ms, 1ms, 1ms, 1ms and last one 1.053ms. 1 ms sounds like traj_period. Try changing traj_period in the ini file and see what happens to the delay

Re: [Emc-developers] Change in feed override during machine run causes 1 milisecond stalls

2006-12-25 Thread Mario .
I am sending a link to my configuration files, since this mail-in system is confusing. Third attempt: INI files for the setup I use, plus some changed demo NC code that tries to run very fast, as fast as the machine possibly can, good for testing accel/ max speed setup. It can be downloaded