Re: [Emc-users] limit switch error

2008-04-26 Thread John Thornton
Don't feel bad those guys are so fast at making improvements that the documents can't keep up either LOL... John On 25 Apr 2008 at 19:45, Jon Elson wrote: John Thornton wrote: On 25 Apr 2008 at 11:16, Jon Elson wrote: With my controllers, for instance, there are 3-line stanzas for

[Emc-users] limit switch error

2008-04-25 Thread mike
I'm getting an axis error on axes 0 1 3 it says joint (0,1,3) on limit switch error but i don't have any limit switches and axis 3 isn't even plugged in. how do I clear this so i can turn the machine on? - This SF.net email

Re: [Emc-users] limit switch error

2008-04-25 Thread John Thornton
If you used stepconf to generate your config then run it again and unselect the limit switches. They will be on the page with the I/O config for your parallel port. If not then you will have to manually comment the lines out in the hal file that pertain to limit switches. To make a line a

Re: [Emc-users] limit switch error

2008-04-25 Thread John Thornton
On 25 Apr 2008 at 11:16, Jon Elson wrote: With my controllers, for instance, there are 3-line stanzas for each limit switch, such as : newsig Xminlim bit linksp Xminlim = ppmc.0.din.01.in linksp Xminlim = axis.0.neg-lim-sw-in Jon Jon the new format is a single line using net. I

Re: [Emc-users] limit switch error

2008-04-25 Thread Jon Elson
John Thornton wrote: On 25 Apr 2008 at 11:16, Jon Elson wrote: With my controllers, for instance, there are 3-line stanzas for each limit switch, such as : newsig Xminlim bit linksp Xminlim = ppmc.0.din.01.in linksp Xminlim = axis.0.neg-lim-sw-in Jon Jon the new format is a single