Re: [expert] OT - HW RAID Config Issue

2001-01-13 Thread civileme
On Saturday 13 January 2001 05:30, you wrote: I just wanted a quick sanity check. I've installed a Mylex AcceleRAID 170 (see earlier note) with three Cheetah's attached. After almost every reboot, the controller reports a drive failure on the disk closest to the controller, but with the

[expert] OT - HW RAID Config Issue

2001-01-12 Thread John J. LeMay Jr.
I just wanted a quick sanity check. I've installed a Mylex AcceleRAID 170 (see earlier note) with three Cheetah's attached. After almost every reboot, the controller reports a drive failure on the disk closest to the controller, but with the highest SCSI id, 2. There was one exception where the