Re: [HCP-Users] Volumetric subcortical group-averaged data: what is the exact MNI template you used?

2019-04-06 Thread Xavier Guell Paradis
This means that the template is asymmetric, not symmetric, correct? Thanks, Xavier. On Fri, Apr 5, 2019 at 5:48 PM Glasser, Matthew wrote: > FSL’s MNI152. > > Matt. > > From: on behalf of Xavier Guell > Paradis > Date: Friday, April 5, 2019 at 4:46 PM > To: "hcp-users@humanconnectome.org" >

Re: [HCP-Users] MR ICA+FIX error

2019-04-06 Thread Marta Moreno
Dear Tim, I am getting the following error: hcp_fix_multi_run - ABORTING: Unsupported MATLAB run mode value (FSL_FIX_MATLAB_MODE) in /usr/local/bin/gaurav_folder_new/HCP/Connectome_Project_3_22/Pipelines/ICAFIX/hcp_fix_multi_run/settings.sh: In settings.sh, I have set up the following: #

Re: [HCP-Users] MR ICA+FIX error

2019-04-06 Thread Glasser, Matthew
I would use mode=1 Matt. From: mailto:hcp-users-boun...@humanconnectome.org>> on behalf of Marta Moreno mailto:mmorenoort...@icloud.com>> Date: Saturday, April 6, 2019 at 2:46 PM To: Timothy Coalson mailto:tsc...@mst.edu>> Cc: HCP Users mailto:hcp-users@humanconnectome.org>> Subject: Re:

Re: [HCP-Users] MR ICA+FIX error

2019-04-06 Thread Harms, Michael
This indicates that you aren’t using the version of hcp_fix_multi_run from the v4.0.0 pipelines, which supports the use of all 3 matlab modes. -- Michael Harms, Ph.D. --- Associate Professor of Psychiatry Washington University School of