Edward Jaffe wrote:
John McKown wrote:
We pressed for a parallel sysplex, but it was too expensive and
not worth the cost ($175,000 US for a CFL was what I was told we
were quoted. Firm price, no futher discounts, pay up or forget it.)
ITYM an ICF not CFL (Canadian Football League). $175K
On the workstation, Tom Brennan's Vista tn3270
Set code page to International (euro) (which is 1140)
CP1140 is 037 with Euro, International with Euro is CP1148
(CP500 w/o Euro)
--
Peter Hunkeler
Credit Suisse
--
For IBM-MAIN
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER p ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE
Hunkeler Peter (KIUK 3) wrote:
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER p ON THE DD STATEMENT
On Mon, 7 Apr 2008 09:05:36 +0200, Hunkeler Peter (KIUK 3) wrote:
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m ON THE DD STATEMENT
IEFC620I
RON,
You do intend to create a company? Your website says otherwise. In
fact, the
way it reads you are not the owner of MFNETDISK, you are the Chief
Developer. The website says We are in the progress of establishing a
small
company that specializes in the Network Disk Storage area
HI,
Since some of you, maybe the majority think like them, criticize my posting
about MFNetDisk (Hijackings...), I decide to stop posting any messages to
this forum.
You will never see any messages of mine in your MF forum.
Thanks and good luck,
Shai
hi listers,
I would like to restart the JES2 standalone one by one in turn , in a sysplex
image. what are the specificaly steps to consider ? Thanks for any advisement !
Sincerely,
Laurence
_
聰明搜尋和瀏覽網路的免費工具列 — MSN 搜尋工具列
Hi Ed,
Re. you saying:
. And remember, unlike
general CPs, specialty engines are carried forward for life.
Specifically, if you buy an ICF now, you will get one included, at no
extra charge, on every replacement/upgrade System z processor you
purchase from IBM in the future.
Is this true
Jim, as a long time resident of the list you must know that I am going to
say TSSO. It even has a mechanism to reply to the correct IMS system.
Regards
Dave
--
For IBM-MAIN subscribe / signoff / archive access instructions,
I choked on my coffee this morning, ROTFLMAO. I just hope the MF in the post
below meant MainFrame. Sorry, I just could not resist.
Lindy Mayfield [EMAIL PROTECTED] wrote: From the main page
(http://www.mfnetdisk.com) I clicked on the free
link then on the link that says Free Movie Tutorial
Is this true too for zIIPs zAAPs?
I suppose it's not for IFLs?
It's true for all the specialty engines.
The arrangement came out before zIIPs zAAPs and was originally announced for
IFLs.
-
Too busy driving to stop for gas!
On Mon, 7 Apr 2008, shai hess wrote:
HI,
Since some of you, maybe the majority think like them, criticize my posting
about MFNetDisk (Hijackings...), I decide to stop posting any messages to
this forum.
You will never see any messages of mine in your MF forum.
Thanks and good
Hi Ted (and/or Ed),
Is this documented somewhere in an official IBM document?
jan
- Oorspronkelijk bericht -
Van: Ted MacNEIL [mailto:[EMAIL PROTECTED]
Verzonden: maandag, april 7, 2008 12:05 PM
Aan: IBM-MAIN@BAMA.UA.EDU
Onderwerp: Re: Specialty Engine Prices (Was: Another RNL question)
From the main page (http://www.mfnetdisk.com) I clicked on the free
link then on the link that says Free Movie Tutorial and it offered to
find me a date.
Classy. (-:
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of shai hess
Sent: 7.
Laurence,
Could you provide more details on what you are looking to do? What do you
mean to restart JES2 standalone?
HOT START JES2 one at a time, QUICK START, or some other process.
JES2 in a MAS will not WARM start easily once the other systems are up.
Plus, JES2 is smarter today than it was
The following message is a courtesy copy of an article
that has been posted to bit.listserv.ibm-main,alt.folklore.computers as well.
re:
http://www.garlic.com/~lynn/2008g.html#18 CA ESD files Options
http://www.garlic.com/~lynn/2008g.html#19 CA ESD files Options
John McKown wrote:
Although I did say that I was uninterested in your product and was not
really keen on the postings, I am sorry that you feel that you must leave. I
do know that some of us come across strongly. I've learned to ignore some of
the messages of that type.
I do know that others
Alan Altmark wrote:
On Fri, 4 Apr 2008 15:35:00 -0400, Tony Harminc [EMAIL PROTECTED]
wrote:
So I think this is simply a question of the PC-side display font and
input method. I think you need to talk to Tom about how he maps EBCDIC
data to display fonts. I see in the Vista Thick font supplied
Paul Gilmartin wrote:
On Mon, 7 Apr 2008 09:05:36 +0200, Hunkeler Peter (KIUK 3) wrote:
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m ON THE DD STATEMENT
Hi,
If you have access, you can look in the system log.
Tools like OPC will capture the end of job event and then do something.
Well, I need to do this in a program. Could you bring me in the right
direction and tell me how I can capture the SYSLOG?
My problem is that I submit a job and
You can also check SMF.
Can SMF be monitored (and how?) or do I need to SMF to a file and
parse the file?
Thank you,
Michael
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED]
Michael
Off the top of my head I can think of the following options (outside of any job
scheduling software solution).
(1) Use the IEFACTRT exit (job/step termination exit) - however this might be
overkill for you.
(2) Write an assembler program that always gets control as the last job step
In this case you will need to research the reason for the 3 ptf's
described in your previous post to have failed. Once that is corrected,
all should be OK.
By any chance is this a new install? In those cases, I have often found
it helpful to receive/apply/accept the base functions first, and then
He said he doesn't want another step at EOJ that writes a I have run
dataset. The problems with 1 and 2 are: What would you do with the
information you glean? You have to FTP it back or save it in a dataset.
The only two options I see so far is to submit a job that reads SYSLOG, or
submit a job
snip
It seems there's a limitation that SMS won't allow multivolume
allocation.
/snip
Horse manure!
Code your JCL with Unit=(sysda,n) where N is the number of volumes
required to hold the data. I usually code unit=(SYSDA,59) (the max
allowed). There is also a discussion in the manual about the
hi Lizette,and all
Because I'm trying to build newer userexits which are called by JES2 , to
prevent high cost of rolling IPL, so that the JES2 must be WARM start one by
one in the MAS.
Can anybody advise specific steps to do with that ?
Sincerely,
Laurence
Date: Mon, 7 Apr
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of R.S.
Hunkeler Peter (KIUK 3) wrote:
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Paul Gilmartin
Sent: Sunday, April 06, 2008 8:58 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: INDEX() or POS() string functions in Enterprise COBOL?
Snipped
Boyer-Moore?
Linkname:
Michael Knigge wrote:
Hi,
If you have access, you can look in the system log.
Tools like OPC will capture the end of job event and then do something.
Well, I need to do this in a program. Could you bring me in the right
direction and tell me how I can capture the SYSLOG?
My problem is
On Fri, 4 Apr 2008 21:58:27 -0700, Gregory Pinkowski
[EMAIL PROTECTED] wrote:
Repeat after me, the 3-zeros chant:
Kilo
Mega
Giga
Tera
Peta
Exa
(and in the other direction):
Milli
Micro
Nano
Pico
Femto
Atto
http://searchstorage.techtarget.com/sDefinition/0,,sid5_gci499008,00.html
--
Mark Zelden
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of Ted MacNEIL
Sent: Monday, April 07, 2008 5:06 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: Specialty Engine Prices (Was: Another RNL question)
Is this true too for zIIPs zAAPs?
I suppose
Laurence,
I believe the only way to get a WARM START in JES2 is to have all systems (MVS,
z/OS) down and then bring up one. Once JES2 is up I think only QUICK START or
HOT STARTS are available.
What level of JES2 and what exits are you working with? There is a $T command
to enable and
Alan,
The problem that Jason is having is that his extended forat datasets will
not extend to a new volume once the initial allocation and extents are full,
or there is no more space on the original volume. As I recall, this is the
behaviour for DSOR=PS striped datasets whether you allocate your
Jason,
This is one of the fun features of DSORG=PS striped datasets. Good practice
for striped datasets is to allocate the Primary Space to be the expected
size of the dataset. This is because you cannot rely on overflowing your
datasets to more volumes once you are out of space on any volume
I have been trying to access the IBM Publications Server for days.
All I can get are the following messages:
Our apologies
The Publication Internet server is busy. Please try again later.
Please use your browser's Back button, to return to the previous page.
Has anyone been
In a message dated 4/7/2008 7:50:05 A.M. Central Daylight Time,
[EMAIL PROTECTED] writes:
My problem is that I submit a job and some time later I need to know if
the job has run **AND** which was the return-code (best: condition code
of every step).
The IVP's for System build have an
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of John P. Baker
Sent: Monday, April 07, 2008 10:41 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: IBM Publications Server
I have been trying to access the IBM Publications Server for days.
All I
Elardus,
I disagree.
If Shai is this thin skinned when so many posts are trying to offer him
constructive advice then it is his problem. He has a good idea, he has a
patent that covers it, and he proved it can work. Good for him.
But he did go beyond some of the behaviour expected on the
On Mon, 7 Apr 2008 06:41:46 -0600, Steve Comstock wrote:
The LISTSERV doesn't process HTML; it uses plain text.
I get a pop-up selection that says:
Plain Text
HTML
... But I left it at the default, Plain text
I'm curious why you didn't just code amp;SYSEXEC in the first place.
I did
On Mon, Apr 7, 2008 at 10:58 AM, Farley, Peter x23353
[EMAIL PROTECTED] wrote:
SNIP
. Programmers who are fluent in COBOL are not limited to that
language skill, they are only limited by what business will pay them to
support.
Exactly. In many shops, a COBOL programmer who coded a
On Mon, 7 Apr 2008 06:41:46 -0600, Steve Comstock wrote:
The LISTSERV doesn't process HTML; it uses plain text.
I'm curious why you didn't just code amp;SYSEXEC in the first place.
[Now I'll wait to see how this comes through on the actual
message, just to verify.]
Trying with a different
The primary IBM Publications Server is located at:
http://www.elink.ibmlink.ibm.com/publications/servlet/pbi.wss?CTY=USnull;
When I try to search for a publication, I get the error message. This has
been happening for days.
John P. Baker
-Original Message-
From: IBM Mainframe
On Mon, 2008-04-07 at 08:31 -0700, Ron Hawkins wrote:
If you are using data rate to allocate your stripes
Isn't that the *only* way to control striping? My notes say you get one
stripe for every 4MB/sec you specify in Sustained Data Rate.
(I have STRIPED2, STRIPED4 and STRIPED8 storage
Beercool
If I ever said that I would never post again because of some balling I may
as well just roll over...
I get more BS from my Ex's.lol..
What ever I get here at least I really deserve .lol
--
Email
Paul Gilmartin wrote:
On Mon, 7 Apr 2008 06:41:46 -0600, Steve Comstock wrote:
The LISTSERV doesn't process HTML; it uses plain text.
I get a pop-up selection that says:
Plain Text
HTML
... But I left it at the default, Plain text
I'm curious why you didn't just code amp;SYSEXEC
Hi all ,
I installed apache geronimo 5.2.1 on Z/OS .1.7
I start geronimo from omvs shell and from BPXBATCH .
Now I want start the application server under JVM .
I installed the IBM SDK and I have java 1.5 .
How I must write the JCL procedure .
Can someone help me
The list prices for IFL, zIIP zAAP have no bearing on ICF. IBM charges more
for an ICF than the other specialty engines, and I'm not sure that the free
upgrade applies either.
Edward Jaffe [EMAIL PROTECTED] 4/7/2008 2:54 AM
Edward Jaffe wrote:
John McKown wrote:
We pressed for a parallel
I get the same behaviour. I tried the Advanced Search link and got:
We encountered a system difficulty in processing your request. Please
try again. If the difficulty persists, please contact us via the 'Feedback'
or 'Customer Support' facility.
If you have been seeing problems for several
Franco,
What you probably want to do is to start the JVM under the IBM JZOS Batch
Launcher, which is part of the IBM Java SDK for z/OS.
To do this, download the User's Guide from here:
http://www-03.ibm.com/servers/eserver/zseries/software/java/jzos/overview.html
Following the instructions in
David,
You can allocate the stripe chunks using a Guarenteed Space STORCLAS and
UNIT COUNT specified in the DTACLAS or JCL. In this case it will always give
you stripes equal to the UNIT COUNT with space for each chunk equal to the
Primary space requested. My experience is that this is more
Ron Hawkins wrote:
Although he won't read this, I wish him luck ...
Past experience has shown that people who claim to leave the list in
anger, disgust, or after some sort of humiliation, never do. They
continue to monitor and eventually post again.
I'll offer this wager... If Shai Hess
-snip
Beercool
If I ever said that I would never post again because of some bawling I
may as well just roll over...
I get more BS from my Ex's.lol..
What ever I get here at least I really deserve .lol
Jan Vanbrabant wrote:
Hi Ted (and/or Ed),
Is this documented somewhere in an official IBM document?
jan
I'm not sure exactly where this is documented in the maze of IBM
announcements and related material. But, in this February 2008 IT Jungle
article by Hesh Wiener, he summarizes the
-snip--
Past experience has shown that people who claim to leave the list in
anger, disgust, or after some sort of humiliation, never do. They
continue to monitor and eventually post again.
I'll offer this wager... If Shai Hess does not post to
I wonder why when we went from a z890 to a z9BC, I lost my IFL?
I don't know, either.
But, I do know of shops where it worked.
For confidentiality reasons, I cannot name them.
-
Too busy driving to stop for gas!
--
For IBM-MAIN
Franco,
I am pretty sure that you can use the JZOS that comes with the 1.5 JDK.
Please see
http://dovetail.com/forum/viewtopic.php?p=1506
Kirk and Steve at Dovetail might chime in.. but it looks like running
Geronimo has been covered in the Dovetail forum.
Rob Schramm
Sirius Computer
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of Rick Fochtman
Sent: Monday, April 07, 2008 12:03 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: My last post in this forum.
[snip]
a character fault. It's like after the 30th or 40th time you
---snip---
If Shai is this thin skinned when so many posts are trying to offer him
constructive advice then it is his problem. He has a good idea, he has a
patent that covers it, and he proved it can work. Good for him.
IBMLink down due to Web Identity (login) problems
ETA 2:30PM
This email/fax message is for the sole use of the intended
recipient(s) and may contain confidential and privileged information.
Any unauthorized review, use, disclosure or distribution of this
On Mon, 7 Apr 2008 08:31:03 -0500, Staller, Allan wrote:
In this case you will need to research the reason for the 3 ptf's
described in your previous post to have failed. Once that is corrected,
all should be OK.
Agreed.
By any chance is this a new install? In those cases, I have often found
it
Shameless plug here; not to be repeated.
For those of you who are users of my ARCHIVER (www.cbttape.org, File
147): I'm preparing to unbutton it for major upgrades. If you have
suggestions for new features, improvements, corrections, etc., please
contact me OFFLIST with your comments, etc.
On 7 Apr 2008 10:17:30 -0700, [EMAIL PROTECTED] (McKown,
John) wrote:
Ah, that brings back memories. Programmer insisted that since S0C7 was a
system abend, that meant is was a system problem and we needed to fix
the system! Same programmer, on DOS/VS, would get PROGRAM REQUESTED
TERMINATION
--snip
a character fault. It's like after the 30th or 40th time you
get a call
telling you that your new Operating System caused a S0C7 in someone's
application. I can't speak for everyone, but I tend to get a
[snip]
Ah, that brings back
Check the CBT tape. There is a JES2 exit 5 that will create the ability to
dynamically re-load JES2 exits. Try file 198. Or possibly file 346.
On Mon, 7 Apr 2008 11:17:14 -0400, Lizette Koehler [EMAIL PROTECTED]
wrote:
Laurence,
I believe the only way to get a WARM START in JES2 is to have
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Rick Fochtman
FUD ???
Shortened form of FUDSI: Fear, Uncertainty, Doubt, Superstition,
Ignorance. Like what we see in politics. :-(
-jc-
--
When we try to FTP from our Sandbox to our production mainframe we get the
following:
,EZA1456I Connect to ?,
ucdhs1
,EZA1554I Connecting to: ucdhs1.ucdmc.ucdavis.edu 152.79.1.130 port: 21.,
,220-FTPD1 IBM FTP CS V1R7 at UCDHS1.UCDMC.UCDAVIS.EDU, 18:06:57 on
2008-04-07.,
,220 Connection will
-snip
FUD ???
Shortened form of FUDSI: Fear, Uncertainty, Doubt, Superstition,
Ignorance. Like what we see in politics. :-(
--unsnip---
Methinks in politicians we see a lot more SID; subterfuge, ignorance
and
Joh,
What security subsystem are you running ? RACF, ACF2 or Top- Secret ? Are
there any other messages on the z/OS master con.
Regards,
Scott Ford
Senior Host Developer | Forging Enterprise Identity | IdentityForge.com
(Main) 678.266.3399 x304 | (Cell) 609.346.0399 | (Fax) 678.266.3399
[EMAIL
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of John Norgauer
Sent: Monday, April 07, 2008 1:11 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: FTP serious error... HELP!
When we try to FTP from our Sandbox to our production
mainframe we get
According to the FTP RFC a 2 in the first digit means:
2yz Positive Completion reply
The requested action has been successfully completed. A
new request may be initiated.
a 5 in the second digit means:
x5z File system - These replies indicate the status of
We are downloading Z/os 1.9 Serverpac but I cant see how I touched our
production system.
We are RACF
I am not sure what UNIX message catalog is out of sync with your ftp
server code is all about.
Any more pointers?
John Norgauer
University of California Davis Medical Center
2315 Stockton Blvd
We have a problem with an application that use the SMFEWTM macro in 24-bit mode.
When used on z/OS 1.9 it seems that the return is made in 31-bit mode. Has
anyone else encountered this?
--
For IBM-MAIN subscribe / signoff /
--snip
We have a problem with an application that use the SMFEWTM macro in 24-bit mode.
When used on z/OS 1.9 it seems that the return is made in 31-bit mode. Has
anyone else encountered this?
-unsnip
Sounds like a
- Original Message -
From: John Norgauer [EMAIL PROTECTED]
Newsgroups: bit.listserv.ibm-main
Sent: Monday, April 07, 2008 2:10 PM
Subject: FTP serious error... HELP!
When we try to FTP from our Sandbox to our production mainframe we get the
following:
,EZA1456I Connect to ?,
ucdhs1
In [EMAIL PROTECTED], on 04/04/2008
at 09:20 AM, Steve Comstock [EMAIL PROTECTED] said:
Tom has been terrific, but I'm still not there. Any suggestions?
Does your 3270 simulator support GE? At least one common 3270 CECP has
brackets at inconvenient code points preceded by GE, but ISPF
In [EMAIL PROTECTED], on 04/07/2008
at 09:10 AM, R.S. [EMAIL PROTECTED] said:
Lower case characters. Strictly forbidden in JCL.
Try AMP
That's just as illegal.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO position; see http://patriot.net/~shmuel/resume/brief.html
We don't
In [EMAIL PROTECTED], on
04/03/2008
at 10:31 PM, shai hess [EMAIL PROTECTED] said:
Just to make it clear..MF is much better host than PC for production
work only if it stay less open that the PC.
Making it clear isn't the same as making it true.
Sometime I feel that I need a lawyer to
In [EMAIL PROTECTED],
on 04/07/2008
at 09:05 AM, Hunkeler Peter (KIUK 3)
[EMAIL PROTECTED] said:
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m ON THE DD STATEMENT
In [EMAIL PROTECTED], on 04/05/2008
at 09:10 AM, Paul Gilmartin [EMAIL PROTECTED] said:
Yeah. Right. And how may the programmer refer in one step to a PDS, and
in another to one of its members? I regularly do:
//GENER EXEC PGM=IEBGENER
//SYSUT2 DD
In [EMAIL PROTECTED],
on 04/04/2008
at 02:56 PM, Timothy Sipples [EMAIL PROTECTED] said:
PROFS is still around, although the new name (and new version) is now
OfficeVision.
No; OV/VM may be PROFS, but OV/MVS is quite different.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO
In [EMAIL PROTECTED], on 04/03/2008
at 02:41 PM, Brad Wissink [EMAIL PROTECTED] said:
We currently are using PSF download to send purchase orders to
InfoPrint/AIX V4.1 and then faxing from there to the vendor. We have
learned that fax support will no longer be included in InfoPrint on any
In
[EMAIL PROTECTED],
on 04/04/2008
at 11:04 AM, Stocker, Herman [EMAIL PROTECTED] said:
I believe that the JES reader is 80 characters.
Not unless they've changed things. But I believe that the FTP server only
writes to the Internal reader, so even if you could get it to write other
than 80
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of John Norgauer
Sent: Monday, April 07, 2008 1:20 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: FTP serious error... HELP!
We are downloading Z/os 1.9 Serverpac but I cant see how I touched
When I execute the TSO FTP command either using ISPF option 6 or exiting ISPF
entirely and entering FTP a the ready prompt, I get the following abend and
error message.
CEE5101C During initialization, the callable service BPX1MSS failed. The system
return code was 000156 , the
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of David Day
Sent: Monday, April 07, 2008 2:19 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Debugging TSO FTP command
When I execute the TSO FTP command either using ISPF option 6
or exiting
What component owns CEE5101C?
CEE is the prefix for LE.
And, the module abending under ISPF is an initialisation routine for LE.
Do you have LE in the link list?
-
Too busy driving to stop for gas!
--
For IBM-MAIN subscribe /
On Mon, 7 Apr 2008 14:02:19 -0300, Shmuel Metz (Seymour J.)
[EMAIL PROTECTED] wrote:
//SYSEXEC DD DISP=(OLD,PASS),DSN=amp;amp;SYSEXEC
Trying the amp;, I get:
IEFC620I UNIDENTIFIABLE CHARACTER a ON THE DD STATEMENT
IEFC620I UNIDENTIFIABLE CHARACTER m ON THE DD STATEMENT
John,
Thanks. I tried it using logonid IBMUSER and it took me straight in. I
just have to figure out now how to set my normal userid with the proper
attributes.
--Dave Day
- Original Message -
From: McKown, John [EMAIL PROTECTED]
Newsgroups: bit.listserv.ibm-main
To:
Anybody saw in the NY times what the IBM CEO received for his efforts last
year ?
If I remember correctly, it was about 20 Million Dollars. In ONE YEAR.
http://www.nytimes.com/2008/04/06/business/06comp.html?
pagewanted=1_r=1sq=executives%20salariesst=nytamp;scp=2
Anton
It should be in upper case
Edouard A. Myers
Acting Manager of Technical Services
Office of the Chief Technology Officer
DC Government
222 Massachusetts Ave, NW, Suite 200
Washington, DC 20001
Phone : 202-727-4017
Fax: 202-727-3880
Email: [EMAIL PROTECTED]
Website:
Anton,
He's in the minor leagues compared to James Simons (watch the wrap):
http://www.nytimes.com/2007/04/24/business/24hedge.html?ei=5090en=22f49
c03f5ef88ebex=1335067200partner=rssuserlandemc=rsspagewanted=all
Tom Harper
-Original Message-
From: IBM Mainframe Discussion List
-Original Message-
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of David Day
Sent: Monday, April 07, 2008 2:53 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: Debugging TSO FTP command
John,
Thanks. I tried it using logonid IBMUSER and it took me
IBM Mainframe Discussion List IBM-MAIN@BAMA.UA.EDU wrote on 04/07/2008
02:46:48 PM:
We have a problem with an application that use the SMFEWTM macro in
24-bit mode.
When used on z/OS 1.9 it seems that the return is made in 31-bit mode.
Has
anyone else encountered this?
There was a
Hi,
You referring to the Hedge Fund Managers ?
But this is another kettle of fish that is rotten (VROT)...
Based on the discussions I follow on the PBS channel, the Hedge FUnd Mess
and the subsequent 30 Billion Republican bail out was because of the lact
of Regulation by Greenspan.
Your
John:
I saw the same msg several weeks ago but it turned out that both systems were
just coming up. Once they came up again, it went away. Commercial controls in
an application will trip if the msg # returned is not what it is expecting.
Bill
Date: Mon, 7 Apr 2008 11:10:57 -0700 From:
IBM Mainframe Discussion List IBM-MAIN@BAMA.UA.EDU wrote on 04/07/2008
04:28:50 PM:
Is there something easier than looking at the home address space storage
off
of CR15?
CBF cr15value ASID(x'homeasid') STR(LS)
Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY
Anton,
The point I was trying to make is that the compensation package for the
IBM CEO, compared to others heading up large corporations and compared
to other very bright people, such as James Simons, did not strike me as
unusual or excessive, or out-of-line in any way, especially considering
how
Thanks again John. I added an OMVS segment to the group my userid is
associated with and a GID(1) to the segment, and I now have access to FTP
from the ISPF option 6 command line.
-Dave Day
- Original Message -
From: McKown, John [EMAIL PROTECTED]
Newsgroups:
Thanks for the hint.
I tried TEST with L 10.%+C4%+7C% L(12) C and got .00..SSS2HKR
Does that indicate interception?
The level is SP7.0.9 FMID HBB740
- Original Message -
From: Jim Mulder [EMAIL PROTECTED]
Newsgroups: bit.listserv.ibm-main
To: IBM-MAIN@BAMA.UA.EDU
Sent: Monday, April 07,
1 - 100 of 119 matches
Mail list logo