Hi,
same issue here with OMSA 6.2 not detecting PERC anymore on PE2950,
I tried restarting OMSA services and rebooting, but the issue persists.
I have many 2950 with this issue after the nightly update.
Same issue on PowerEdge R410
Thanks a lot,
Giuseppe
Il 17/12/2009 8.45, Dirk Gfroerer
I am hoping someone can let me know where I am going wrong here. I am
trying to set a custom sring on 12 new r710s. All are running Debian
Etch, and have the OMSA tools re-packaged by SARA (5.5.0-5).
The command:
./omconfig chassis frontpanel lcdindex=1 config=custom text=txt
The result:
Error!
Non of our servers can now see the storage elements:
# srvadmin-services.sh status
dell_rbu (module) is running
ipmi driver is running
dsm_sa_datamgrd (pid 23010) is running
dsm_sa_eventmgrd (pid 23122) is running
dsm_sa_snmpd (pid 23181) is running
dsm_om_shrsvcd (pid 23256) is running
On my machines I noticed ipmi was not fully unloading. Here is what we
did to fix it:
* Stop OMSA
- srvadmin-services.sh stop
* Stop haldaemon - it was determined that for some reason haldaemon was
hanging on to the ipmi modules...
- service haldaemon stop
- pkill hald-addon*
* Make
Not sure if I should continue top-posting, but ...
Tried your fix on a PE2950 - unfortunately, no
joy :-(
Dimitri
On Thursday 17 December 2009 1:34:47 pm Aaron
McKinnon wrote:
On my machines I noticed ipmi was not fully
unloading. Here is what we did to fix it:
* Stop OMSA
-
Ryan writes:
The command:
./omconfig chassis frontpanel lcdindex=1 config=custom text=txt
The result:
Error! Invalid LCD Index.
You don't need to use OMSA to set the LCD; you can use syscfg from the DTK
(http://support.us.dell.com/support/downloads/format.aspx?releaseid=R240491),
or the
On Wed, Dec 16, 2009 at 2:01 PM, jeffrey_l_mend...@dell.com wrote:
Hi All,
The OpenManage 6.2 yum repository has just been posted, and 'latest' symlink
updated:
http://linux.dell.com/repo/hardware/latest/
The repo contains OMSA 6.2 which adds support for the T110, R210, T310, and
R510
Philip Tait wrote:
We want to attach an MD1000 to a PE2900 in a non -RAID configuration.
The Dell sales people are very convinced that we have to have a PERC6/E
to connect an MD1000, but they are doing further research.
We have two MD1000 attached to a PE2950. We have a PERC5/E. With the
On 12/17/2009 11:39 AM, Jose-Marcio Martins da Cruz wrote:
Philip Tait wrote:
We want to attach an MD1000 to a PE2900 in a non -RAID configuration.
The Dell sales people are very convinced that we have to have a PERC6/E
to connect an MD1000, but they are doing further research.
We have two
I'm also seeing this issue, and no luck with the workaround either. (Plus I
had to manually unload the ipmi module-stopping the service didn't do it).I
opened a support case and he tried suggested to use the driver from the website
- v00.00.03.21 instead of the 00.00.04.08 in the
10 matches