RE: Help with local omsa mirror

2010-05-19 Thread Ryan Miller
Yes, it's a python script that generates a bash script. So the python script isn't executing on the webserver for whatever reason, and you're just returning the script contents on GET. -Original Message- From: linux-poweredge-boun...@dell.com [mailto:linux-poweredge-

RE: non-Dell hard drives attached to PERC H700 and H800

2010-04-13 Thread Ryan Miller
Domsch Sent: Wednesday, April 14, 2010 1:24 AM To: Bond Masuda Cc: Shane Williams; 'linux-poweredge@dell.com' Subject: Re: non-Dell hard drives attached to PERC H700 and H800 On Tue, Apr 13, 2010 at 09:30:20AM -0400, Ryan Miller wrote: Shane, FY's are always the year the real year ends

RE: openmanage 6.2 / missing controller issue fixed ?

2010-03-24 Thread Ryan Miller
Cc: Nielsen, Steve; Ryan Miller; linux-poweredge@dell.com Subject: Re: openmanage 6.2 / missing controller issue fixed ? On 03/19/2010 02:57 PM, Brandon Ooi wrote: This series of commands works for all of my RHEL/Centos machines. yum -y install procmail OpenIPMI chkconfig --level 345 ipmi

RE: openmanage 6.2 / missing controller issue fixed ?

2010-03-24 Thread Ryan Miller
...@gmail.com] Sent: Wednesday, March 24, 2010 8:59 PM To: Ryan Miller Cc: r...@linux.com; Nielsen, Steve; linux-poweredge@dell.com Subject: Re: openmanage 6.2 / missing controller issue fixed ? there are other software packages that implement IPMI (freeipmi?) On Wed, Mar 24, 2010 at 5:55 PM, Ryan Miller

RE: openmanage 6.2 / missing controller issue fixed ?

2010-03-19 Thread Ryan Miller
Did you actually install srvadmin-all ? I know it seems like it should work with just the storage packages, but I think some of the underlying services are set up by other packages. 6.2 is now working for me with clean install on CentOS 5 with PERC6i and SAS5i controllers. Haven't tried it

RE: RAID battery-backed cache - necessary? (was: Linux-PowerEdge Digest, Vol 68, Issue 35)

2010-02-10 Thread Ryan Miller
It's about write caching. Fsync() can't return (and thus, e.g., your sql transaction can't return committed) until the data is on durable storage (that's what the D in ACID means). Battery-backed cache on the controller counts, because if you pull the plug, the data will still get to disk.

RE: ***POSSIBLE SOLUTION*** OM 6.2 Broken Storage Section

2009-12-18 Thread Ryan Miller
From: jeffrey_l_mend...@dell.com [mailto:jeffrey_l_mend...@dell.com] Sent: Friday, December 18, 2009 12:12 PM To: Ryan Miller; linux-powere...@lists.us.dell.com Subject: RE: ***POSSIBLE SOLUTION*** OM 6.2 Broken Storage Section Ryan, Thanks for the report on the firmware update exception. What

RE: ***POSSIBLE SOLUTION*** OM 6.2 Broken Storage Section

2009-12-18 Thread Ryan Miller
Just to get this out into Google for anybody else that's been having trouble rolling back to 6.1, I ended up with the following order of operations: 1.Replace the .repo file with the OMSA_6.1-specific version (replace latest with OMSA_6.1 2. Yum remove libsmbios srvadmin*

***POSSIBLE SOLUTION*** OM 6.2 Broken Storage Section

2009-12-17 Thread Ryan Miller
I'm also seeing this issue, and no luck with the workaround either. (Plus I had to manually unload the ipmi module-stopping the service didn't do it).I opened a support case and he tried suggested to use the driver from the website - v00.00.03.21 instead of the 00.00.04.08 in the