A recent fix which made sure ->degraded was initialised properly
exposed a second bug - ->degraded wasn't been updated when drives
failed or were hot-added.

Signed-off-by: Neil Brown <[EMAIL PROTECTED]>

### Diffstat output
 ./drivers/md/multipath.c |    2 ++
 1 file changed, 2 insertions(+)

diff .prev/drivers/md/multipath.c ./drivers/md/multipath.c
--- .prev/drivers/md/multipath.c        2006-10-23 16:34:54.000000000 +1000
+++ ./drivers/md/multipath.c    2006-10-23 16:35:38.000000000 +1000
@@ -277,6 +277,7 @@ static void multipath_error (mddev_t *md
                        set_bit(Faulty, &rdev->flags);
                        set_bit(MD_CHANGE_DEVS, &mddev->flags);
                        conf->working_disks--;
+                       mddev->degraded++;
                        printk(KERN_ALERT "multipath: IO failure on %s,"
                                " disabling IO path. \n Operation continuing"
                                " on %d IO paths.\n",
@@ -336,6 +337,7 @@ static int multipath_add_disk(mddev_t *m
                                blk_queue_max_sectors(mddev->queue, 
PAGE_SIZE>>9);
 
                        conf->working_disks++;
+                       mddev->degraded--;
                        rdev->raid_disk = path;
                        set_bit(In_sync, &rdev->flags);
                        rcu_assign_pointer(p->rdev, rdev);
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html