Dear all,
I am working with integration of solar energy to grid. I am
implementing it with negative loading concept. So to prevent reverse power
flow I included the following codings.
if(et11mpc.bus(42,PD))
mpc.bus(42,PD)=mpc.bus(42,PD)-et11;
else
et11=0;
end
Thank you both so much for the help. That is what i needed.
All the best.
On 4/21/2015 11:02 AM, Jose Luis Marin wrote:
I found a copy here:
http://www.mail-archive.com/matpower-l@cornell.edu/msg01301.html
But I don't know if it really matches the actual RTS-96 data (see
Dear Ray,
No Ray, It was made as if solar generator generates more power than
actual load then that solar generation is not required. this may reduce the
solar power into the system but avoids reverse power flow due to negative
load.